VERTICAL CONTACT TOASTER

P/N 1010840 Rev. M 07/14

TEMPERATURE CONTROL PANEL
NOTE: The term “set point temperature” refers to the

desired temperature setting.

To display the actual Platen temperature—providing it is

over 440°F (227° C)—press the

TEMP UP button.

To display the actual Auxiliary Air Heater temperature—

providing it is over 360°F (182°C)—press the

TEMP

DOWN button.

To switch the temperature display between Fahrenheit

(°F) and Celsius (°C), press and hold the

TEMP SCALE

button for 5 seconds.

PLATEN HEATER TEMPERATURE ADJUSTMENT
1. Turn the Rocker Switch on and wait for the

Temperature Display to finish the power up

sequence (Figure 4).

2. Press and hold the

TEMP UP and TEMP DOWN

buttons for over 1 second until the display flashes

the Platen set point temperature, then release

(Figure 5).

3. Press the

TEMP UP button to raise the set point

temperature or press the

TEMP DOWN button to

lower the set point temperature.

NOTE: The Maximum Platen Set point Temperature

is 600°F (315°C). If no change in temperature is made

within 5 seconds, the display reverts back to the pre-

vious set point.

4. Release the button when the desired set point is

displayed.

AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT
1. Turn the Rocker Switch on and wait for Temperature

Display to finish the power up sequence (Figure 4).

2. Press and hold the

TEMP UP and TEMP SCALE

buttons for over 1 second until the display flashes

the set point temperature, then release (Figure 6).

3. Press the

TEMP UP button to raise the set point

temperature or press the

TEMP DOWN button to

lower the set point temperature.

NOTE: The maximum Auxiliary Air Heater Set point

Temperature is 400°F (204°C).

4. Release the button when the desired set point is

displayed.

NOTE: If no change in temperature is made within 5

seconds, the display reverts back to the previous set

point.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

SP - P

600

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

400

SP - A

Figure 4. Temperature Power Up Sequence

3. SP-A (Set Point Auxiliary)

is displayed

1. SP-P (Set Point Platen)

is displayed

“Heat On” LED will blink on/off during warm up and when either

platen or auxiliary air heaters are calling for heat.

2. Current Platen Set Point

Temperature setting is shown

4. Current Auxiliary Air Set Point

Temperature is shown

5. “LO” is displayed until

platen temperature rises

above 550°F (288°C)

6. "USE" is displayed when

Platen Set Point Temperature*

is reached

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

LO

USE

* Platen set point temperature must be between

460°F (238°C) and 600°F (315°).

OPERATION (continued)