Vertical contact toaster, Sp - p 600, 400 sp - a – A.J. Antunes & Co VCT-2000 9210410 User Manual
Page 9: Lo use, Operation (continued)
![background image](/manuals/432693/9/background.png)
9
VERTICAL CONTACT TOASTER
P/N 1010840 Rev. M 07/14
TEMPERATURE CONTROL PANEL
NOTE: The term “set point temperature” refers to the
desired temperature setting.
To display the actual Platen temperature—providing it is
over 440°F (227° C)—press the
TEMP UP button.
To display the actual Auxiliary Air Heater temperature—
providing it is over 360°F (182°C)—press the
TEMP
DOWN button.
To switch the temperature display between Fahrenheit
(°F) and Celsius (°C), press and hold the
TEMP SCALE
button for 5 seconds.
PLATEN HEATER TEMPERATURE ADJUSTMENT
1. Turn the Rocker Switch on and wait for the
Temperature Display to finish the power up
sequence (Figure 4).
2. Press and hold the
TEMP UP and TEMP DOWN
buttons for over 1 second until the display flashes
the Platen set point temperature, then release
(Figure 5).
3. Press the
TEMP UP button to raise the set point
temperature or press the
TEMP DOWN button to
lower the set point temperature.
NOTE: The Maximum Platen Set point Temperature
is 600°F (315°C). If no change in temperature is made
within 5 seconds, the display reverts back to the pre-
vious set point.
4. Release the button when the desired set point is
displayed.
AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT
1. Turn the Rocker Switch on and wait for Temperature
Display to finish the power up sequence (Figure 4).
2. Press and hold the
TEMP UP and TEMP SCALE
buttons for over 1 second until the display flashes
the set point temperature, then release (Figure 6).
3. Press the
TEMP UP button to raise the set point
temperature or press the
TEMP DOWN button to
lower the set point temperature.
NOTE: The maximum Auxiliary Air Heater Set point
Temperature is 400°F (204°C).
4. Release the button when the desired set point is
displayed.
NOTE: If no change in temperature is made within 5
seconds, the display reverts back to the previous set
point.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
SP - P
600
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
400
SP - A
Figure 4. Temperature Power Up Sequence
3. SP-A (Set Point Auxiliary)
is displayed
1. SP-P (Set Point Platen)
is displayed
“Heat On” LED will blink on/off during warm up and when either
platen or auxiliary air heaters are calling for heat.
2. Current Platen Set Point
Temperature setting is shown
4. Current Auxiliary Air Set Point
Temperature is shown
5. “LO” is displayed until
platen temperature rises
above 550°F (288°C)
6. "USE" is displayed when
Platen Set Point Temperature*
is reached
TEMP
UP
TEMP
DOWN
TEMP
SCALE
°F
°C
POWER
LO
USE
* Platen set point temperature must be between
460°F (238°C) and 600°F (315°).
OPERATION (continued)