Vertical contact toaster, Operation, Operating instructions – A.J. Antunes & Co VCT-2000 9210410 User Manual

Page 8: Temperature adjustments

Advertising
background image

VERTICAL CONTACT TOASTER

8

P/N 1010840 Rev. M 07/14

NOTE: The toaster is tested and shipped with the heaters

set at the above recommended temperatures.

OPERATION

Figure 3. Bun Thickness Adjustment Controls

Operating Instructions

1. Set the Bun Thickness Adjustment Controls

(Figure 3) to desired setting.

NOTE: Recommended settings are #2 for heel and

#6 for crown.

2. Turn the Rocker Switch on. (Figure 2). Allow the

toaster to warm-up for 30 minutes before pro-

ceeding.

NOTE: The temperature display (Figure 2) will flash

“LO” until the toaster reaches its preset operating

temperature. When the toaster approaches the pre-

set temperature of 600°F (315°C), “USE” appears

in the temperature display and the unit is ready to

toast buns. If “USE” does not appear in the window

after warm-up period of approximately 30 minutes,

contact your Authorized Service Agency.

3. Drop Crowns and Heels into the slot (Figure 2).

Cut sides of heel and crown must face each

other.

4. Toasted buns will drop into the bun landing area

(Figure 2).

5. Test at least four buns before putting the toaster

into service.

6. Turn the Rocker Switch off when finished toasting

for the day and proceed with the

Daily Cleaning

as outlined in the Maintenance section of this

manual.

Temperature Adjustments

The VCT-2000 uses a Platen Heater and two Auxiliary

Air Heaters. The Platen Heater consists of a heating

element built into the Platen to toast the cut side of

the bun. The two Auxiliary Heaters assist in provid-

ing additional heat to the buns. The first Auxiliary Air

Heater is located between the conveyor in the front

of the toaster. The second Auxiliary Heater is located

between the conveyor at the rear of the unit.

RECOMMENDED TEMPERATURES

Recommended temperature setting for the Platen heat-

er is 600°F (315°C).

Recommended temperature setting for the Auxiliary Air

Heaters is 400°F (204°C).

1

2

4

5

1 = 1/2"(12.7mm)
2 = 5/8"(15.9mm)

3 = 11/16"(17.5mm)

6 = 7/8"(22.2mm)

THICKNESS

THICKNESS

1

2

3

4

6

6

5

4 = 3/4"(19.1mm)

5 = 13/16"(20.6mm)

3

Bun Thickness

Adjustment Control

(See Figure 3)

Bun Landing Area

Rocker

Switch

Temperature

Controls

& Temperature

Display

Hi-Limit

Reset

Power

Cord

Figure 2. VCT-2000 Toaster

1

2

4

5

1 = 1/2"(12.7mm)
2 = 5/8"(15.9mm)

3 = 11/16"(17.5mm)

6 = 7/8"(22.2mm)

THICKNESS

THICKNESS

1

2

3

4

6

6

5

4 = 3/4"(19.1mm)
5 = 13/16"(20.6mm)

3

Advertising