Maintenance, 3 regular maintenance work – Karcher HD 7-250 De Tr1 User Manual

Page 77

Advertising
background image

Wartung.pm6.5 - GB

Page 4.7

Maintenance

BOGE Operating instructions for CM 9 series screw compressor module

1

2

Check:

– Prior to commissioning/start-up of the compressor.

– Then every 1000 operating hours,

however at least once a year.

Topping up: – When the oil level has dropped below the "min." mark

(see sketch).

ATTENTION!
Always use the same oil type when topping up.
Never mix different oil types and brands.

– Switch off the compressor using the OFF button.

CAUTION: Risk of injury!
Switch off the main switch and secure against unintentional switching-on.

– Close e.g. ball valve at the compressed air outlet.

– Vent the compressor (as described in the beginning of the chapter).

– Wait approx. 3 minutes to permit the oil to settle.

CAUTION: Risk of injury!
Danger of burning due to hot oil!

– Remove plug of oil filling socket .

– Check oil level.

The oil level must not drop below the "min." mark (see sketch).

– If necessary, top up with oil to the lower edge of the thread ("max." mark)

on the oil filling socket.

– Screw plug back in.

– Open ball valve at the compressed air outlet.

4.3

Regular maintenance work

Checking the oil level,
topping up oil

Fig. 4.3: Checking the oil level, topping up with oil