Define Limit Pattern Values
:CALCulate:LLINe[1]:DATA
<x-axis>,<ampl>{,<x-axis>,<ampl>}
:CALCulate:LLINe[1]:DATA?
This command defines limit pattern values, and
destroys all existing data. A N9340A allows you to
set as many as four points to compose the limit
pattern by connecting them together.
•
<x-axis> – are values in frequency or time
domain as specified by
:CALCulate:LLINe[1]:PATtern:DOMain.
•
<ampl> – amplitude values are in the current
Y- axis units. A N9340A provides you four
choices for Y- axis units: uV, mV, - dBm, dBm.
*RST State:
Off
Key Access:
[Limit] > {Set Pattern}
Domain
Valid Unit
Frequency
Hz, kHz, MHz, GHz
Time
us, ms, s, ks