17 mains voltage components, 1 door interlock adjustment – Merrychef eikon e4s User Manual

Page 36

Advertising
background image

36

Service & Parts Manual original Instructions

Part Number 32Z3871 US

Issue 3

SW1

SW2

SW3

SW3

L1

N

SW1

SW2

L1

N

TESTING

C

OMPONENT

S

6

5

3

2

1

SW1

SW2

SW3

17 MAINS VOLTAGE COMPONENTS

17.1 Door Interlock Adjustment

Located on the door hinges are 3 safety interlock
microswitches, to prevent microwave emissions
escaping when the oven door is opened:

The Primary (SW3) breaks the electrical supply
circuit to the transformers.

The Secondary (SW2) breaks the microwave circuit if
the primary fails.

The Monitor switch (SW1) will short out the
Microwave circuit blowing the fuse if both Primary
and Secondary interlocks fail.

IMPORTANT: in the event that the Monitor
switch causes the Microwave circuit fuse to
blow, the Secondary (SW2) and Monitor (SW1)
microswitches must be replaced due to exposure
from high short-circuit currents.

The purpose of the following adjustment procedure
is to set the interlock to switch off the Microwave
circuit when the door is opened more than 4mm
and for the Microwave circuit to operate when the
door is closed and the door seal expands.

17.1.1 Door Interlock Adjustment procedure:
17.1.2 Disconnect and isolate the oven from the
electricity supply.
17.1.3 Allow the oven to cool down.
17.1.4 Remove the oven casing.
17.1.5 Ensure that the High Voltage Capacitor is
discharged before commencing work.
17.1.6 Door Spacer Kit SA1109

1

Position Green 2mm spacers over the top
corners of the door seal and carefully close the
door ensuring the spacer is still in position.

2

Slacken the pivot screw.

3

Release the adjusting screws and move the
backplate until microswitch SW3 just activates
then secure all screws.

4

Open door to replace the Green 2mm spacers
with Red 4mm spacers and close the door.

5

Slacken the pivot screw.

6

Release the adjusting screws and move the
backplate until microswitch SW2 just activates
then secure all screws.

7

Remove the spacers, then open and close the
oven door 5-10 times.

IMPORTANT: CHECK THE SWITCHES OPERATE IN
THE FOLLOWING SEQUENCE AS MICROSWITCH SW3
MUST SWITCH THE LOAD CURRENT.

Closing the door:

¦

SW1 opens fi rst

¦

SW2 closes second

¦

SW3 closes third

Opening the door:

¦

SW3 opens fi rst

¦

SW2 opens second

¦

SW1 closes third

OVEN DOOR OPEN

OVEN DOOR CLOSED

Advertising