49

ELEC

TRIC

AL

CIR

CUIT

S

8

1

2

3

4

5

6

12

11

7

9

10

23.3 SRB LED’s

©

P-Bus - Irregular fl ashing, indicating data

communication with QTS.

©

Run - Pulsing 1 second fl ash, indicating that the

board has booted up.

©

12v & 5v - Lit to show voltage outputs from

inboard transformer.

©

Relay & Triac - Lit to show that a signal has been

sent to energise that component.

1

Cooling fan.

2

Convection fan.

3

Stirrer.

4

5v supply.

5

12v supply.

6

Heater safety.

7

Heater drive.

8

P-BUS: fl ashes when data is being sent /
received. RUN: 1 second fl ash.

9

Oven Door.

10

Microwave safety relay.

11

Microwave 2 drive.

12

Microwave 1 drive.

13

LED (Lit to show that signal is recieved via

overheat trips). if lit it is ok.