Wash Pump/Heater Will not Operate

Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:

Verify that LED #1 (Power On) is illuminated. If LED #1 is not illuminated,
check:

• Main power connection and wiring
• Fuse inside the control enclosure
• Bi-metallic disc switch for water temperature (switch must be closed

if water temperature is below 120°F)

• Bi-metallic disc switch for motor temperature (switch must be

closed if motor temperature is below 150°F)

Check to see that the Liquid Level LEDs #3 and #4 are illuminated when
the wash tank is filled to the waterline.

If either one or both of the lights are not illuminated:

• Clean the liquid level sensors as described in the “Preventive

Maintenance” section of this manual.

• Be sure that all connections to and from the liquid level sensors are

secure and that there is no physical damage to the wiring.

• If damage to connectors and/or wiring is found, contact Power Soak

Systems, Inc. at 800-444-9624.

If the above troubleshooting guidelines do not correct the problem, it will be
necessary to contact Power Soak Systems, Inc. at 1-800-444-9624.