Vaddio CeilingVIEW HD HideAway User Manual

Page 13

Advertising
background image

CeilingVIEW HD HideAway Manual

CeilingVIEW HD HideAway Manual, Document Number 342-0289 Rev. B

Page 13 of 24

Note: Anytime the PowerRite 24VDC, 2A Power Supply is disconnected from the CeilingVIEW HD HideAway
Power Interface, the Boot-Up Procedure/Upper and Lower Limits Program in the CeilingVIEW HD HideAway will
be repeated once power is reconnected. This procedure will take approximately one minute to complete.

STEP 5: System Power on and use of Diagnostic LED Lights on the Main Printed Circuit Board (PCBA)

















To assist installers to troubleshoot and diagnose problems, the Main Printed Circuit Board (PCBA) includes the
following Diagnostic LED light indicators:

1) Camera Power Blue LED: The Camera Power Blue LED light will be on whenever there is Camera Power

being sent to the Vaddio ClearVIEW HD PTZ Camera (from a Vaddio Quick-Connect DVI/HDMI SR or a
Vaddio Quick-Connect SR).


2) Camera RS232 Green LED: When a serial code is transmitted from the RS-232 to the Camera Control Port

of a Vaddio Quick-Connect DVI/HDMI SR or a Vaddio Quick-Connect SR, the Camera RS-232 Diagnostic
Green LED will flash or blink to indicate a code has been received at the Main Printed Circuit Board (PCBA).
Note: This can be a very quick blink or it may not trigger due to a very short code sequence.


3) QC RS-232 Green LED: When a serial code is transmitted from the RS-232 to Camera Control Port of a

Vaddio Quick-Connect DVI/HDMI SR or a Vaddio Quick-Connect SR, the RS-232 Diagnostic Green LED will
flash or blink to indicate a code has been sent from the Quick-Connect.

4) Lift Trigger Green LED: The Lift Trigger Diagnostic Green LED light will be on when the Lift Trigger Contact

Closure on the CeilingVIEW HD HideAway Power Interface is closed (which results in the lift going down and
the Vaddio Camera powering on). The CeilingVIEW HD Hideaway Camera Lift will continue to stay down
until the Lift Trigger Contact Closure is opened. When the Lift Trigger Contact is opened, the Camera Lift will
retract back into the CeilingVIEW HD HideAway and power down the Vaddio ClearVIEW HD PTZ Camera.


5) Lift Calibrate Yellow LED: The Yellow LED will turn on when lift calibration is activated. To activate Lift

Calibration, the Blue Power LED must be on steady in the CeilingVIEW HD HideAway Trim Ring Assembly
and the Camera Lift is inside the CeilingVIEW HD HideAway. Press and hold the Calibration push button on
the IR Circuit Board in the Trim Ring Assembly until Blue Power light is flashing (see Instructions for
Calibrating: Setting the Upper and Lower Lift Stops). The Yellow LED on the Main Printed Circuit Board
(PCBA) will turn on. The Yellow LED will turn off when the Lift Calibration is de-activated

6) Lift Power Blue LED: A Blue LED will be on when Lift Power/Lift Trigger from the CeilingVIEW HD HideAway

Power Interface is detected in the Main Printed Circuit Board (PCBA).


Note:
The Diagnostic LED’s on the Main Printed Circuit Board (PCBA) are visible with the Front Access Panel
removed. However, the Safety Interlock Switch on the upper left side of the CeilingVIEW HD HideAway back box
will not allow operation of the CeilingVIEW HD HideAway Lift Actuator with the Front Access Panel removed.

The Main

Printed Circuit
Board (PCBA)

Diagnostic

LED’s on the

Main Printed

Circuit Board

(PCBA)

LED’s 1-6

(Top to

Bottom)

Figure 20: Location of Diagnostic LED’s on
the Main Printed Circuit Board (PCBA)

Figure 21: Diagnostic LED’s Label on the Main Printed
Circuit Board (PCBA) Security Cover.