Evi-d80n/d80p/d90n/d90p commands, 29 command list – Vaddio EVI-D80D90 Tech User Manual

Page 29

Advertising
background image

29

Command List

EVI-D80N/D80P/D90N/D90P Commands

EVI-D80N/D80P/D90N/D90P Command List (1/3)

Command Set

Command

Command Packet

Comments

AddressSet

Broadcast

88 30 01 FF

Address setting

IF_Clear

Broadcast

88 01 00 01 FF

I/F Clear

CommandCancel

8x 2p FF

p: Socket No. (=1 or 2)

CAM_Power

On

8x 01 04 00 02 FF

Power ON/OFF

Off

8x 01 04 00 03 FF

CAM_Zoom

Stop

8x 01 04 07 00 FF

Tele (Standard)

8x 01 04 07 02 FF

Wide (Standard)

8x 01 04 07 03 FF

Tele (Variable)

8x 01 04 07 2p FF

p=0 (Low) to 7 (High)

Wide (Variable)

8x 01 04 07 3p FF

Direct

8x 01 04 47 0p 0q 0r 0s FF

pqrs: Zoom Position

CAM_DZoom

On

8x 01 04 06 02 FF

Digital zoom ON/OFF

Off

8x 01 04 06 03 FF

CAM_Focus

Stop

8x 01 04 08 00 FF

Far (Standard)

8x 01 04 08 02 FF

Near (Standard)

8x 01 04 08 03 FF

Far (Variable)

8x 01 04 08 2p FF

p=0 (Low) to 7 (High)

Near (Variable)

8x 01 04 08 3p FF

Direct

8x 01 04 48 0p 0q 0r 0s FF

pqrs: Focus Position

Auto Focus

8x 01 04 38 02 FF

AF ON/OFF

Manual Focus

8x 01 04 38 03 FF

Auto/Manual

8x 01 04 38 10 FF

One Push Trigger

8x 01 04 18 01 FF

One Push AF Trigger

Infinity

8x 01 04 18 02 FF

Forced infinity

Near Limit

8x 01 04 28 0p 0q 0r 0s FF

pqrs: Focus Near Limit Position

AF Sensitivity

Normal

8x 01 04 58 02 FF

AF Sensitivity High/Low

Low

8x 01 04 58 03 FF

CAM_AFMode

Normal AF

8x 01 04 57 00 FF

AF Movement Mode

Interval AF

8x 01 04 57 01 FF

Zoom Trigger AF

8x 01 04 57 02 FF

Active/Interval Time

8x 01 04 27 0p 0q 0r 0s FF

pq: Movement Time, rs: Interval

CAM_IRCorrection

Standard

8x 01 04 11 00 FF

FOCUS IR compensation data switching

IR Light

8x 01 04 11 01 FF

CAM_ZoomFocus

Direct

8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w
FF

pqrs: Zoom Position
tuvw: Focus Position

CAM_WB

Auto

8x 01 04 35 00 FF

Normal Auto

Indoor

8x 01 04 35 01 FF

Indoor mode

Outdoor

8x 01 04 35 02 FF

Outdoor mode

One Push WB

8x 01 04 35 03 FF

One Push WB mode

Manual

8x 01 04 35 05 FF

Manual Control mode

One Push Trigger

1) 6)

8x 01 04 10 05 FF

One Push WB Trigger

CAM_RGain

Reset

8x 01 04 03 00 FF

Manual Control of R Gain

Up

8x 01 04 03 02 FF

Down

8x 01 04 03 03 FF

Direct

8x 01 04 43 00 00 0p 0q FF

pq: R Gain

CAM_BGain

Reset

8x 01 04 04 00 FF

Manual Control of B Gain

Up

8x 01 04 04 02 FF

Down

8x 01 04 04 03 FF

Direct

8x 01 04 44 00 00 0p 0q FF

pq: B Gain

Advertising