42 command list pan/tilt status code list, Pan/tilt position (for reference), Led status – Vaddio EVI-D80D90 Tech User Manual

Page 42

Advertising
background image

42

Command List

Pan/Tilt Status Code List

P

Q

R

S

- - - - - - - - 0 - - - - - - 1 A Pan movement all the way to the left
- - - - - - - - 0 - - - - - 1 - A Pan movement all the way to the right
- - - - - - - - 0 - - - - 1 - - A Tilt movement all the way up
- - - - - - - - 0 - - - 1 - - - A Tilt movement all the way down
- - - - - - - - - - 0 0 - - - - Pan movement is correct
- - - - - - - - - - 0 1 - - - - Pan position cannot be detected
- - - - - - 0 0 0 - - - - - - - The Tilt movement is correct
- - - - - - 0 1 0 - - - - - - - The Tilt position cannot be detected
- - - - 0 0 - - 0 - - - - - - - No movement instructions
- - - - 0 1 - - 0 - - - - - - - In the midst of a Pan/Tilt
- - - - 1 0 - - 0 - - - - - - - Pan/Tilt completed
- - - - 1 1 - - 0 - - - - - - - Pan/Tilt failed

- - 0 0 - - - - 0 - - - - - - - Not initialized
- - 0 1 - - - - 0 - - - - - - - Initializing

- -1 0 - - - - 0 - - - - - - - Initialization completed
- -1 1 - - - - 0 - - - - - - - Initialization failed

( - : optional)

Pan/Tilt Position (for reference)

Parameter (position)

PAN

E1E5 (-170 degree) to 1E1B (+170 degree)

TILT

FC75 (-20 degree) to 0FF0 (+90 degree) (IMAGE FLIP: OFF)
F010 (-90 degree) to 038B (+20 degree) (IMAGE FLIP: ON)

LED Status

Status

POWER (Green)

STANDBY (Orange)

Main power ON Power On (including initializing period)

On

Off

When receiving infrared signals form Remote Commander

Blinking

Off

At position detection error

On

Blinking

Standby status
Power off by VISCA or the Remote Commander

Off

On

Main power Off

Off

Off

Initialization
error

Pan/tilt error

Blinking

Blinking

Internal error(LSI, etc.)

Blinking alternately

BOTTOM
switch

Setting error
(Example: when the BOTTOM switch 5 is set to ON.)

On

On