Visca command setting values, 39 command list, Exposure control (1/2) – Vaddio EVI-D80D90 Tech User Manual

Page 39

Advertising
background image

39

Command List

VISCA Command Setting Values

Exposure Control (1/2)

NTSC (s)

PAL (s)

Shutter Speed

15

1/10000

1/10000

14

1/6000

1/6000

13

1/4000

1/3500

12

1/3000

1/2500

11

1/2000

1/1750

10

1/1500

1/1250

0F

1/1000

1/1000

0E

1/725

1/600

0D

1/500

1/425

0C

1/350

1/300

0B

1/250

1/215

0A

1/180

1/150

09

1/125

1/120

08

1/100

1/100

07

1/90

1/75

06

1/60

1/50

05

1/30

1/25

04

1/15

1/12

03

1/8

1/6

02

1/4

1/3

01

1/2

1/2

00

1/1

1/1

Iris

11

F1.4 (F1.35)

10

F1.6

0F

F2

0E

F2.4

0D

F2.8

0C

F3.4

0B

F4

0A

F4.8

09

F5.6

08

F6.8

07

F8

06

F9.6

05

F11

04

F14

03

F16

02

F19

01

F22

00

CLOSE

* Number in ( ) applies to EVI-D90N/P only.

Gain

0F

+28 dB

0E

+26 dB

0D

+24 dB

0C

+22 dB

0B

+20 dB

0A

+18 dB

09

+16 dB

08

+14 dB

07

+12 dB

06

+10 dB

05

+8 dB

04

+6 dB

03

+4 dB

02

+2 dB

01

0 dB

00

–3 dB

Gain Limit

0F

+28 dB

0E

+26 dB

0D

+24 dB

0C

+22 dB

0B

+20 dB

0A

+18 dB

09

+16 dB

08

+14 dB

07

+12 dB

06

+10 dB

05

+8 dB

04

+6 dB

Advertising