Specification

Revision 1.02

FnBus PIO N/A

Page 21

0x1022(4130)

Read

1word

Watchdog error counter, it is cleared by writing address 0x1020

0x1023(4131)

Read/Write

1word

Enable/disable auto recovery Watchdog error when receiving new frame.
0:Disable, 1:Enable(default). Its value is stored in EEPROM.

0x1028(4136)

Read

4word

I/O update time, Fnbus Process time, CoDeSys update time, CoDeSys
Process Time.

(1usec unit)

3.2.4.

Adapter Information Special Register (0x1100, 4352)

Address

Access

Type, Size

Description

0x1100(4352)

Reserved.

0x1101(4353)

Reserved.

0x1102(4354)

Read

1word

Start address of input image word register. =0x0000

0x1103(4355)

Read

1word

Start address of output image word register. =0x0800

0x1104(4356)

Read

1word

Size of input image word register.

0x1105(4357)

Read

1word

Size of output image word register.

0x1106(4358)

Read

1word

Start address of input image bit. = 0x0000

0x1107(4359)

Read

1word

Start address of output image bit. =0x1000

0x1108(4360)

Read

1word

Size of input image bit.

0x1109(4361)

Read

1word

Size of output image bit.

0x110D(4365)

Read/Write

1word

Enable/Disable Auto Reboot when FnBus, 0:Disable(Default)

0x110E(4366)

Read

upto
33word

Expansion slot’s ST-number including NA
First 1word is adapter’s number, if NA-9379, then 0x9379

0x1110(4368)

Read

1word

Number of expansion slot

0x1111(4369)

Read

1word

Number of active slot

0x1112(4370)

Read

1word

Number of inactive slot

0x1113(4371)

Read

upto
33word

Expansion slot Module Id. Refer to Appendix A.1 Product List.
First 1word is adapter’s module id.

0x1114(4372)*

Read/Write

1word

Input process image mode. The default value is 2.
Valid value range is from 0 to 3.

0x1115(4373)*

Read/Write

1word

Output process image mode. The default value is 0.
Valid value range is from 0 to 1.

0x1116(4374)
**

Read/Write

2word

Inactive slot list, The corresponding bit represents slot position.
0:Active slot, 1:Inactive slot.
Ex) if value is 0x0001, 0x8000, then slot#1,#32 are inactive slots

0x1117(4375)

Read

2word

Live slot list. , The corresponding bit represents slot position.
1:live slot, 0:not live slot

0x1118(4376)

Read

2word

Alarm slot list.
The corresponding bit represents slot position.
1:Alarm slot, 0:Normal slot

0x1119(4377)

Read

1word

Hi byte is ModBus status, low byte is FnBus status.
It is identical with address 0x1040.

0x111A(4378)

Write

1word

Reserved. Adapter Scan command.

0x111B(4379)

Read/Write

1word

Reserved. IO State machine.

0x111C(4380)

Read

2word

Reserved. Runtime fault code.

0x111D(4381)

Read

1word

Adapter FnBus Revision. If 0x013C, FnBus Revision is 1.60

0x111E(4382)

Read

1word

Reserved. Adapter IO identification vendor code.

0x111F(4383)

Read

5word

LED Display Value and Status Code

* ** After the system is reset, the new “Set Value” action is applied.

** If the slot location is changed, set default value automatically (all expansion slot are live).