Changing the torque cylinder – Hawk Industries Hawkjaw Sr. Manual M100K-2GSR Serial Numbers 201 to 370 User Manual

Page 57

Advertising
background image

6. Use the 1 1/8" wrench to slowly

loosen the Cap side Hoses

(CH1), (CH2). Check for fluid
flow
. Bleed any pressure.
Disconnect the Cap side Hoses

(CH1), (CH2).

7. Use the 1" wrench to slowly

loosen the Rod side Hose (RH).
Check for fluid flow. Bleed any
pressure. Disconnect the Rod
side Hose (RH).

8. Pull out the Torque Cylinder

Safety Clip (SC).

9. Use the Torque Cylinder Safety

Clip (SC) to pull out the Torque
Cylinder Rod Pin
(P).

10. Disconnect the Low Torque

Warning System Hydraulic Hoses

(HH & HH1).

11. Use the 1 1/8" wrench and 5/8"

Allen wrench to remove the Top
Torque Cylinder Mount Bolts

(TBH), (TBA).

12. Use the 1 1/8" wrench to remove

all Four Bottom Torque
Cylinder Mount Bolts
(BB).

13. Slide out the Torque Cylinder (C).

14. Remove the Bottom Trunion

Mount Plate (BMP) and the Top

Trunion Mount Plate (TMP).

Continued on next page...

Maintenance & Repair 55

Changing the Torque Cylinder

P

HH1

HH

C

TBH

TBA

TMP

BMP

CH2

CH1

BB

RH

P

SC

Changing the Torque Cylinder

Advertising