Initial Steps

1. Make sure the HawkJaw is off the

drill pipe connection and in the
rest position on the derrick.

2. Use Raise (R) to raise the

HawkJaw 3"-5" inches off the

derrick floor.

3. Shut down the Hydraulic power

unit.

4. Press the Grip button

repeatedly to bleed hydraulic
pressure.

5. Disconnect the Air power supply.

6. Push in the “E” stop (E).

7. Assume that there is still a load

on every actuator. Proceed with

caution.

Air Logic System and Main

Block

1. Use the 7/8" wrench to remove

the Main Block Housing Cover
Plate Bolts
(B) on each side.

2. Remove the Main Block

Housing Cover Plate (CP) to

expose the Main Manifold (M).

E