OPERATION CONTROL

NOT ENOUGH WATER ON THE BRUSH

1. Make sure the tap is open
2. Make sure there is water in the solution tank
3. Clean the solution filter

MACHINE DOES NOT CLEAN EFFECTIVELY

1. Check for brush wear and, if necessary, replace it (the brush should

be replaced as the bristles are about 15 mm long).

2. Use another type of brush and not the standard one. For cleaning

tasks on floors with stubborn dirt, special brushes are
recommended, which can be supplied on request according to
individual requirements.

SQUEEGEE DOES NOT DRY PERFECTLY

1. Make sure the squeegee is clean

2. Adjust the height of the squeegee support (see under

“PREPARATION OF THE MACHINE”)

3. Clean the whole suction unit (see under “WEEKLY

MAINTENANCE”)

4. Replace the rubber blades, if worn out