10

Featuring the new OBS (Octagonal Brush System);

The brushes simply push-fit up onto the chucks making fitting and removal a simple process.
Ensure the Brush deck is set to the appropriate width for the brushes being used (Fig.11a/11b).

Slide the brush under the brush deck (Fig.12).

Fit the brushes onto the OBS drive chuck (Fig.13)

Safety gloves are recommended for the changing of used brushes.

Note:

Check the deck width setting is correct with the selected brushes before use.

Fig.12

Fig.13

Adjustment of the Brush deck must take place with the deck in the raised position.

Lift the Deck locking knob located at the front of the machine. (see Fig.11), then pull the side pod at the handle

position to expand or close to contract the deck to the desired width - 26 inch (see Fig.11a) or 22 inch

(see Fig 11b).

26 inch

Fig.11

Fig.11a

Fig.11b

Note: Use 2x 13 inch Brush size for

26 inch setting.

Note: Use 2x 11 inch Brush size for

22 inch setting.

Note: Remove the brushes before adjusting width!