Lcd display and fault codes, Fig.44 – NaceCare Solutions TTV5565 User Manual

Page 23

Advertising
background image

23

LCD Display

Fault

Possible Cause

Ef

fect on Product

Investigate the Following

Action Required

If Fault

Persists

Blank

* No power

* Key switched of

f

* Emergency stop pressed

* Machine will not operate

*Key switched of

f

* Emergency stop pressed

* Switch key on (page 8)

* Release emergency stop

(page 8)

‘OVER CURRENT’

* Brush over current

* Brush pressure to great.

* Brush current exceeds 32A

* W

rong type of brush for surface

* V

ac. Brush, W

ater &

Detergent motors / pump

will not operate

* Brush LED’

s all flash in

unision until the trigger is

released

* Release brush pressure ( page 14)

* Changed type of brush

* Restart machine.

‘UNDER VOL

TS’

* Battery voltage dropped

below 21 V

olts

* Left most Battery LED

flashes

* Batteries require recharging.

* Faulty cell on battery

* Machine will not operate

* Battery leads and connections

* Charge Bartteries.

* Replace battery

(if cell damaged)

‘ T

ANK FULL

* T

ank full requires emptying

* W

aste

Tank Float switch activated

whilst cleaning or of

f-aisle mode

selected.

* Faulty Float switch

* V

ac. Brush, W

ater &

Detergent motors / pump

will not operate

* T

ank full LED illuminated

* T

op waste tank full

* Empty top waste tank

* Replace switch

‘INHIBITED’

MACHINE INHIBITED - NO OPERA

TION.

Contact Service Agent

To view

TTV 5565 run time information turn the key to the ‘ON’

position.

Press the run-time information button to cycle between the dif

ferent modes.

T =

Total run-time.

V =

Vacuum total run-time.

B =

Brush total run-time.

W=

W

ater Pump total run-time.

Fig.44

LCD Display and fault codes

Advertising