Operation, Safety information, Support and maintenance – NOVUS TxIsoRail 4-20 mA User Manual

Page 3: Limited warranty and limitation of liability

Advertising
background image

NOVUS AUTOMATION

3/3

OPERATION

All input types and the 4-20 mA output current are factory calibrated.
However, if desired by the user, a manual offset trim is implemented to

provide fine adjustments to the signal in the field. This is accomplished by

the front key ZERO, located under the frontal label in order to avoid

accidental adjustments. Using a small tool (2 mm diameter), press and hold

the desired key for at least 2 seconds to increase or decrease the output

current. When the output current is reached, the key must be released.
The offset correction can also be accomplished by the TxConfig software.

See in Figure 3 the Zero Correction field for this purpose. The serial

adaptor can be connected to the transmitter while it is operating in the

process.
The user must choose the sensor and configure the sensor span which best

suit the application. The sensor span must not exceed the maximum range

supported by the transmitter for a particular sensor, neither be lower than the

minimum span.
It is important to note that the transmitter accuracy is related to the total

sensor span of a sensor, regardless of the output scale (span) configured.

Example:

• Pt100; maximum input span of –200 to +650 °C, 0.2 % accuracy.
• Maximum error: 1.2 °C (0.15 % of 800 °C)
• This error is the same no matter if total span is used (-200 to 650 °C)

or a narrower user-defined span is used, like 0 to 100 °C.

Note: When using a Pt100 simulator, make sure the transmitter Pt100

excitation current (0.18 mA) is compatible with the simulator specification.

SAFETY INFORMATION

Any control system design should take into account that any part of the

system has the potential to fail. This product is not a protection or safety

device and its alarms are not intended to protect against product failures.

Independent safety devices should be always provided if personnel or

property are at risk.
Product performance and specifications may be affected by its environment

and installation. It’s user’s responsibility to assure proper grounding,

shielding, cable routing and electrical noise filtering, in accordance with local

regulations, EMC standards and good installation practices.

SUPPORT AND MAINTENANCE

This product contains no serviceable parts inside. Contact our local

distributor in case you need authorized service. For troubleshooting, visit our

FAQ at

www.novusautomation.com

.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

NOVUS warrants to the original purchaser that this product is free from

defects in material and workmanship under normal use and service within

one (1) year from the date of shipment from factory or from its official sales

channel to the original purchaser.
NOVUS liability under this warranty shall not in any case exceed the cost of

correcting defects in the product or of supplying replacement product as

herein provided and upon the expiration of the warranty period all such

liability shall terminate.
For complete information on warranty and liability limitations, check

appropriate section in our web site:

www.novusautomation.com

.

Advertising