Dimensions in mm / electrical connections – NOVUS TP510 User Manual

Page 4

Advertising
background image

Dimensions in mm / electrical connections

T

echnical data subject to change.

EDITION 07/2004

Electromagnetic compatibility:
CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2 and EN 61326-1,
interference emit EN 61000-6-3, EN 61326-1

Interference stability

Test standard

Effects

Electrostatic discharge (ESD)

EN 61000-4-2

No effect

15 kV air, 8 kV contact

High-frequency electromagnetic

EN 61000-4-3

No effect

radiation (HF)

200 V/m, 80 … 1000 Mz

Conducted HF interference

EN 61000-4-6

No effect

30 V, 0.15 ... 80 MHz

Fast transients (burst)

EN 61000-4-4

No effect

4 kV

Surge

EN 61000-4-5

No failure

Line-Line, Line-Case, 500 V, 12 Ohm,

9 µF

1 kV, 42 Ohm, 0.5 µF

Ratiometric Line-Line 500 V, 2 Ohm, 18 µF

Magnetic fields

EN 61000-4-8

No effect

30 A/m, 50 Hz

Insulation voltage

500 VDC (optional 1000 VDC)

No effect

350 VAC (optional 700 VAC)

Interference emit

Test standard

Effects

EN 55022

(CISPR 22)

Conducted interference

0.15...30 MHz

No emission

Radiation from housing

30...1000 MHz, 10 meters

No emission

Huba Control Switzerland

Headquarters

Industriestrasse 17
CH-5436 Würenlos
Phone ++41 (0) 56 436 82 00
Fax

++41 (0) 56 436 82 82

Huba Control France

Agent for:

Internet: www.hubacontrol.com

e-mail: [email protected]

Huba Control Germany

e-mail: [email protected]

Huba Control Netherlands

e-mail: [email protected]

Huba Control United Kingdom

Unit 3 Network Point

Range Road
GB-Witney Oxfordshire OX29 0YD
Phone

01 993 776 667

Fax

01 993 776 671

e-mail: [email protected]

e-mail: [email protected]

Advertising