Warning: Fully tighten the two eyebolts and make sure the threads hold properly. 
 
Pan Mechanism Lock and Release 
Tilt Mechanism Lock and Release 
 
Opening and closing the side covers 
Preparing the warning label 
Find the relamping label on the cover of the movable body and, if necessary, replace it with one of 
the optional multilingual labels located in the projector lamp compartment. 
 
WARNING: Read carefully and meticulously apply the information and instructions given on 
this label. In addition, check it is never removed as it contains important safely information. 
 
 
Fitting the lamp 
Take the new lamp out of its package, loosen the two side ring nuts and insert the lamp in its 
mountings. Finally, screw on the ring nuts. 
 
IMPORTANT: to distribute the beam of light uniformly, the lamp needs to be positioned with the 
protrusion visible on the bulb outside the optical axis of the projector. For this purpose it is 
recommended to turn the protrusion towards one of the side covers. 
 
WARNING: do not touch the lamp’s envelope with bare hands. Should this happen, clean the 
bulb with a cloth soaked in alcohol and dry it with a clean , dry cloth. 
 
Lamp regulation 
Opening and closing the effects compartment 
Removing internal clamps 
Take away the four elastic transit bands from the color and frost filters. 
 
INSTALLATION AND START-UP 
Installing the projector 
Except for when the projector is standing on the floor, it is compulsory to fit the safety chain. These 
need to be secured to the projector framework and then hooked onto the rings on the base of the 
projector and eyebolts screwed into the holes in the base of the projector. 
 
WARNING: Check the plate is correctly secured to the base of the fitting. If the plate has 
been removed, to carry out non-routine maintenance work, reposition it, inserting all 10 
screws and at the same time checking the threads hold properly. 
 
Connecting to the mains supply 
 
Connecting to the control signal line (DMX or RS232/423) 
Use a cable conforming: 2 –pole twisted, shielded, 120 ohm, characteristic impedance, 22-24 
AWG, low capacity. 
Do not use microphone cable or other cable with characteristics differing from those specified. The 
end connections must be made using XLR type 5-pin male/female connectors. If the DMX signal is 
used, a terminating plug must be inserted into the last projector with a resistance of 120 ohm , 
(minimum 1/4W) between terminals 2 and 3. The termination is unnecessary if the signal is used. 
 
IMPORTANT: The wires must not make contact with each other or with the metal casing of the 
connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.