13

AGIP ARNICA SPECIFICATIONS

46

32

Approvals and specifi cations

Viscosity at +104°F (+40°C)

mm

2

/s

45

32

ISO-L-HV

Viscosity at +212°F (+100°C)

mm

2

/s

7.97

6.40

ISO 11158

Viscosity index

/

150

157

AFNOR NF E 48603 HV

Flash point COC

°F (°C)

419 (215)

395.6 (202)

AISE 127

Pour point

°F (°C)

-32.8 (-36) -36 (-32,8)

ATOS Tab. P 002-0/I

Density at +59°F (+15°C)

kg/l

0.87

0.865

BS 4231 HSE

CETOP RP 91 H HV

COMMERCIAL HYDRAULICS

Danieli Standard 0.000.001 (AGIP
ARNICA 22, 46, 68)

EATON VICKERS I-286-S3

EATON VICKERS M-2950

DIN 51524 t.3 HVLP

LAMB LANDIS-CINCINNATI P68, P69 and
P70

LINDE

PARKER HANNIFIN (DENISON) HF-0

REXROTH RE 90220-1/11.02

SAUER-DANFOSS 520L0463

DOT4 SPECIFICATIONS

Approvals and specifi cations

Viscosity at -40°F (-40°C)

mm

2

/s

1.300

SAE J 1703

Viscosity at +212°F (+100°C)

mm

2

/s

2.2

FMVSS 116 - DOT4&DOT3

Dry boiling point

°F (°C)

509 (265)

ISO 4925

Wet boiling point

°F (°C)

338 (170)

CUNA NC 956 DOT4

Density at +59°F (+15°C)

kg/l

1.07

Colour

/

Yellow

Climate control system data

Values

Gas type

Reclin 134a

Gas quantity

1.76 lb (0.8 kg)

Salt spreader system description (optional) (*)

Values

Make - type

Epoke - PM 1.4

Snow brush description (optional) (*)

Values (*)

Make - type

Tuchel - ZKM

Camera kit description (optional) (*)

Values (*)

Make - type

IMEL - Car Vision System

(*) For other data/values of the optional equipment, see the relevant Manuals.

ENVIRONMENTAL CONDITIONS

In the environment where the machine operates, there must not be any danger of explosion.
To avoid inhaling exhaust gas, the machine must be used only where there is a proper ventilation.
The machine operates correctly (*) in the following environmental conditions:

Temperature: +14°F to +104°F (-10°C to +40°C)
Humidity: 30% to 95%

(*) When using the machine at ambient temperatures between +14°F and +32°F (-10°C and 0°C), the dust control system cannot

be used; moreover the water tanks and the dust control system itself must be empty.




Advertising