Permitted indicator values for alignment checks, Alignment measurement guidelines, Attach the dial indicators for alignment – Goulds Pumps 3355 - IOM User Manual

Page 19

Advertising
background image

Installation

Types of alignment checks

Type of check

When it is used

Initial alignment (cold alignment)

Prior to operation when the pump and the driver are at ambient

check

temperature.

Final alignment (hot alignment)

After operation when the pump and the driver are at operating

check

temperature.

Initial alignment (cold alignment) checks

When

Why

Before you grout the baseplate

This ensures that alignment can be accomplished.

After you grout the baseplate

This ensures that no changes have occurred during the grouting
process.

After you connect the piping

This ensures that pipe strains have not altered the alignment.
If changes have occurred, you must alter the piping to remove pipe
strains on the pump flanges.

Final alignment (hot alignment) checks

When

Why

After the first run

This ensures correct alignment when both the pump and the driver
are at operating temperature.

Periodically

This follows the plant operating procedures.

Permitted indicator values for alignment checks

NOTICE:
The specified permitted reading values are valid only at operating temperature. For cold
settings, other values are permitted. You must use the correct tolerances. Failure to do so can
result in misalignment and reduced pump reliability.

When dial indicators are used to check the final alignment, the pump and drive unit are
correctly aligned when these conditions are true:

• The total indicator runout is a maximum of 0.002 in. (0.05 mm) at operating temperature.

• The tolerance of the indicator is 0.0005 in./in. (0.0127 mm/mm) of indicator separation at

operating temperature.

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver

This prevents incorrect measurement.

coupling half together so that the indicator rods
have contact with the same points on the driver
coupling half.
Move or shim only the driver in order to make

This prevents strain on the piping installations.

adjustments.
Make sure that the hold-down bolts for the driver

This keeps the driver stationary since movement

feet are tight when you take indicator measure-

causes incorrect measurement.

ments.
Make sure that the hold-down bolts for the driver

This makes it possible to move the driver when you

feet are loose before you make alignment correc-

make alignment corrections.

tions.
Check the alignment again after any mechanical

This corrects any misalignments that an adjustment

adjustments.

may have caused.

Attach the dial indicators for alignment

You must have two dial indicators in order to complete this procedure.
1. Attach two dial indicators on the pump coupling half (X):

a) Attach one indicator (P) so that the indicator rod comes into contact with the perimeter

of the driver coupling half (Y).
This indicator is used to measure parallel misalignment.

Model 3355 Installation, Operation, and Maintenance Manual

17

Advertising