Discharge piping checklist, Final piping checklist, Discharge piping checklist final piping checklist – Goulds Pumps 3355 - IOM User Manual

Page 25

Advertising
background image

Installation

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Check that the suction piping

slopes upwards from the liquid
source to the pump inlet.
If the pump is not self-priming,

Use a foot valve with a diameter

check that a device for priming the that is at least equivalent to the
pump is installed.

diameter of the suction piping.

Liquid source above the pump

Check

Explanation/comment

Checked

Check that an isolation valve is

This permits you to close the line

installed in the suction piping at a

during pump inspection and main-

distance of at least two times the

tenance.

pipe diameter from the suction

Do not use the isolation valve to

inlet.

throttle the pump. Throttling can
cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Check that the piping is level or

slopes downward from the liquid
source.
Make sure that no part of the

suction piping extends below the
suction flange of the pump.
Make sure that the suction piping

This prevents air from entering the

is adequately submerged below

pump through a suction vortex.

the surface of the liquid source.

Discharge piping checklist

Checklist

Check

Explanation/comment

Checked

Check that an isolation valve is in-

The isolation valve is required for:

stalled in the discharge line.

• Priming
• Regulation of flow
• Inspection and maintenance of the pump

Check that a check valve is installed in The location between the isolation valve and the
the discharge line, between the isola-

pump allows inspection of the check valve.

tion valve and the pump discharge

The check valve prevents damage to the pump and

outlet.

seal due to the back flow through the pump, when
the drive unit is shut off. It is also used to restrain
the liquid flow.

If increasers are used, check that they
are installed between the pump and
the check valve.
If quick-closing valves are installed in

This protects the pump from surges and water

the system, check that cushioning de- hammer.
vices are used.

Final piping checklist

Check

Explanation/comment

Checked

Check that the shaft rotates

Rotate the shaft by hand. Make

smoothly.

sure there is no rubbing that can
lead to excess heat generation or
sparks.

Model 3355 Installation, Operation, and Maintenance Manual

23

Advertising