Bearing maintenance, Ball bearing types, Grease lubrication schedule – Goulds Pumps 3355 - IOM User Manual
Page 36: Lubricating-grease requirements, Regrease the grease-lubricated bearings
Maintenance
Bearing maintenance
Ball bearing types
Grease lubricated bearings
Pump size
Suction side, radial suction
Discharge side, radial and end
suction
1.5 x 2.5-7
6306-C3
5306 A
2.5 x 4-8
6307-C3
5307 A C3
4 x 5-10
6308-C3
2x 7308 BECBM
5 x 6-11
6310-C3
2x 7310 BECBM
Grease lubrication schedule
Pump size
Grease quantity
Re-lubrication intervals
Suction side, Discharge
3550 rpm
2950 rpm
2200 rpm
1750 rpm
1450 rpm
in ounces
side, in
ounces
Operating hours
1.5 x 2.5-7
0.25
0.40
3800
4300
5500
6000
6500
2.5 x 4-8
0.30
0.50
3500
4000
5000
5500
6000
4 x 5-10
0.40
0.75
3300
3800
4500
5000
5500
5 x 6-11
0.55
1.10
2500
3300
4300
4800
5000
Lubricating-grease requirements
Precautions
NOTICE:
• Never mix greases of different consistencies (NLGI 1 or 3 with NLGI 2) or with different
thickeners. For example, never mix a lithium-based grease with a polyurea-based grease.
Doing so may result in decreased performance.
• Remove the bearings and old grease if you need to change the grease type or
consistency. Failure to do so may result in equipment damage or decreased performance.
Grease recommendations based on temperature
Most pumps use Sunoco 2EP grease.
This table shows which brand of grease to use when lubricating the pump.
Brand
When temperature of pumped fluid is less than
350°F (177°C) - NLGI consistency 2
Mobil
Mobilux EP2
Exxon
Unirex N2
Sunoco
Mutipurpose 2EP
SKF
LGMT 2
Regrease the grease-lubricated bearings
NOTICE:
Make sure that the grease container, the greasing device, and the fittings are clean. Failure to
do this can result in impurities entering the bearing housing when you regrease the bearings.
1. Wipe dirt from the grease fittings.
2. Insert the amount of grease as noted in the Grease Lubrication Schedule above through
the grease fitting. If grease comes out the lip seal or the heat flinger, make sure that the
cavity is not completely filled with grease.
3. Wipe off any excess grease.
34
Model 3355 Installation, Operation, and Maintenance Manual