Bearing maintenance, Ball bearing types, Grease lubrication schedule – Goulds Pumps 3355 - IOM User Manual

Page 36: Lubricating-grease requirements, Regrease the grease-lubricated bearings

Advertising
background image

Maintenance

Bearing maintenance

Ball bearing types

Grease lubricated bearings

Pump size

Suction side, radial suction

Discharge side, radial and end
suction

1.5 x 2.5-7

6306-C3

5306 A

2.5 x 4-8

6307-C3

5307 A C3

4 x 5-10

6308-C3

2x 7308 BECBM

5 x 6-11

6310-C3

2x 7310 BECBM

Grease lubrication schedule

Pump size

Grease quantity

Re-lubrication intervals

Suction side, Discharge

3550 rpm

2950 rpm

2200 rpm

1750 rpm

1450 rpm

in ounces

side, in
ounces

Operating hours

1.5 x 2.5-7

0.25

0.40

3800

4300

5500

6000

6500

2.5 x 4-8

0.30

0.50

3500

4000

5000

5500

6000

4 x 5-10

0.40

0.75

3300

3800

4500

5000

5500

5 x 6-11

0.55

1.10

2500

3300

4300

4800

5000

Lubricating-grease requirements

Precautions

NOTICE:

• Never mix greases of different consistencies (NLGI 1 or 3 with NLGI 2) or with different

thickeners. For example, never mix a lithium-based grease with a polyurea-based grease.
Doing so may result in decreased performance.

• Remove the bearings and old grease if you need to change the grease type or

consistency. Failure to do so may result in equipment damage or decreased performance.

Grease recommendations based on temperature

Most pumps use Sunoco 2EP grease.
This table shows which brand of grease to use when lubricating the pump.

Brand

When temperature of pumped fluid is less than
350°F (177°C) - NLGI consistency 2

Mobil

Mobilux EP2

Exxon

Unirex N2

Sunoco

Mutipurpose 2EP

SKF

LGMT 2

Regrease the grease-lubricated bearings

NOTICE:
Make sure that the grease container, the greasing device, and the fittings are clean. Failure to
do this can result in impurities entering the bearing housing when you regrease the bearings.

1. Wipe dirt from the grease fittings.
2. Insert the amount of grease as noted in the Grease Lubrication Schedule above through

the grease fitting. If grease comes out the lip seal or the heat flinger, make sure that the
cavity is not completely filled with grease.

3. Wipe off any excess grease.

34

Model 3355 Installation, Operation, and Maintenance Manual

Advertising