Product warranty – Goulds Pumps 3355 - IOM User Manual

Page 8

Advertising
background image

Introduction and Safety

Personnel requirements

These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized

mechanics. Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical

characteristics of the gas, the vapor, or both present in hazardous areas.

• Any maintenance for Ex-approved products must conform to international and national

standards (for example, IEC/EN 60079-17).

ITT disclaims all responsibility for work done by untrained and unauthorized personnel.

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:

• Only use the product in accordance with the approved motor data.

• The Ex-approved product must never run dry during normal operation. Dry running during

service and inspection is only permitted outside the classified area.

• Before you start work on the product, make sure that the product and the control panel are

isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.

• Make sure that thermal contacts are connected to a protection circuit according to the

approval classification of the product, and that they are in use.

• Intrinsically safe circuits are normally required for the automatic level-control system by the

level regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the

product specification.

• Do not modify the equipment without approval from an authorized ITT representative.

• Only use parts that are provided by an authorized ITT representative.

Description of ATEX

The ATEX directives are a specification enforced in Europe for electrical and non-electrical
equipment installed in Europe. ATEX deals with the control of potentially explosive atmos-
pheres and the standards of equipment and protective systems used within these atmos-
pheres. The relevance of the ATEX requirements is not limited to Europe. You can apply these
guidelines to equipment installed in any potentially explosive atmosphere.

Guidelines for compliance

Compliance is fulfilled only when you operate the unit within its intended use. Do not change
the conditions of the service without the approval of an ITT representative. When you install or
maintain explosion proof products, always comply with the directive and applicable standards
(for example, IEC/EN 60079–14).

Product warranty

Coverage

ITT undertakes to remedy faults in products from ITT under these conditions:

• The faults are due to defects in design, materials, or workmanship.

• The faults are reported to an ITT representative within the warranty period.

• The product is used only under the conditions described in this manual.

• The monitoring equipment incorporated in the product is correctly connected and in use.

• All service and repair work is done by ITT-authorized personnel.

6

Model 3355 Installation, Operation, and Maintenance Manual

Advertising