Troubleshooting

Troubleshooting

Alignment troubleshooting

Symptom

Cause

Remedy

Horizontal (side-to-side) alignment cannot The driver feet are bolt-bound.

Loosen the pump's hold-down bolts, and

be obtained (angular or parallel).

slide the pump and driver until you
achieve horizontal alignment.

The baseplate is not leveled properly and 1. Determine which corners of the base-

is probably twisted.

plate are high or low.

2.

Remove or add shims at the appropri-
ate corners.

3.

Realign the pump and driver.

Vertical (top-to-bottom) alignment cannot The baseplate is not leveled properly and 1. Determine if the center of the base-

be obtained (angular or parallel).

is probably bowed.

plate should be raised or lowered.

2.

Level screws equally at the center of
the baseplate.

3.

Realign the pump and driver.

Operation troubleshooting

Symptom

Cause

Remedy

The flow rate is too low.

The back pressure is too high.

Open the discharge valve a little further.
Reduce the resistance in the discharge
pipe. Clean the filter if necessary.
Use a larger impeller. Make sure to take
note of the available motor power.

The speed is too low.

Increase the speed. Check the available
motor power.
Compare the speed of the motor with the
specified pump speed. See the rating
place.
When you adjust the speed (frequency
transformer), check the reference value
settings.

The impeller diameter is too small.

Use a larger impeller. Check the available
motor power.

The pump and/or pipes are not complete- Fill the pump and/or pipes with liquid.
ly filled with liquid.

Vent the pump and/or pipes.

The pump or suction/intake pipe is

Clean the pipes.

blocked.
There is an air pocket in the pipeline.

Vent the pipes.
Improve the pathway of the pipes.

The NPSH is too low.

Increase the liquid level.
Increase the suction pressure.
Reduce the resistance in the intake/suc-
tion pipe. Change the course and pipe
size, open the shutoff valves, and clean
the filters.

Air is being sucked into the pipes.

Increase the liquid level.
Check that the suction pipe is vacuum-
tight.
Provide valves and fittings in the suction
pipe with water seal.

The direction of rotation is wrong.

Change the motor rotation.

The inner components are suffering from

Replace the worn parts.

wear.
Density and/or viscosity of the pumped

Seek assistance

liquid is too high.

48

Model 3355 Installation, Operation, and Maintenance Manual