Bearing lubrication, Oil volumes, Lubricating-oil requirements – Goulds Pumps 3640 - IOM User Manual

Page 40: Oil volumes lubricating-oil requirements

Advertising
background image

Commissioning, Startup, Operation, and Shutdown

Bearing lubrication

Precautions

WARNING:
Make sure to properly lubricate the bearings. Failure to do so can result in excess heat generation,
sparks, and premature failure.

NOTICE:
Avoid equipment damage. Refer to driver/coupling/gear manufactures IOM for instructions and
recommendations for lubrication.

Pumps are shipped without oil

You must lubricate oil-lubricated bearings at the job site.

Ring oil lubrication

Ring oil-lubricated bearings are standard.Sleeve/ball bearings are optional. Bearing housings
are supplied with constant-level oilers and sight glasses. Make sure that oil rings are properly
seated in the grooves in the shaft.

Pure or purge oil-mist lubrication

Pure or purge oil mist are optional features. Follow the oil-mist generator manufacturer's
instructions. The inlet and outlet connections are located on the top and bottom of the bearing
housing, respectively.

Oil volumes

Oil volume requirements for ball/ball and sleeve/ball bearings

This table shows the required amount of oil for oil-lubricated bearings.

All frames in this table use a Watchdog Oiler, which has a capacity of 4 oz. (118 ml).

Size

Nameplate radial

Bearing housing oil volume

bearing

ounces

milliliters

S

6407

22

651

M

6309

L

6312

35

1035

XL1
XL2

6217

58

1715

XL3

6317

72

2129

XL4

6320

89

2632

XL5

6224

Oil volume requirements for sleeve/Kingsbury type bearings

The sleeve/Kingsbury type bearing is a pressurized lubrication system where oil is flowed into
the bearing. This system does not have an oil sump. The system requires a flow rate of 0.5
gpm (0.12 m

3

/hr) for the sleeve bearing and 1.0 gpm (0.23 m

3

/hr) for the Kingsbury bearing at

15 psi (100 kPA).

Lubricating-oil requirements

Oil quality requirements

Use a high-quality turbine oil with rust and oxidation inhibitors with rated viscosity shown below
at 100°F (38°C).

38

Model 3640 Installation, Operation, and Maintenance Manual