Maintenance

Notice that the bearing is pinned to the bearing housing.

5. Remove the dowel pins (469J) that hold the lower half of the bearing housing to the casing

flange.

6. Loosen and remove the nuts (427J) that hold the bearing housing in place.
7. Rotate the lower half of the sleeve bearing (117) around the shaft (122) in order to remove

the bearing from the lower housing.

8. Remove the lower half of the bearing housing.