Commissioning, Startup, Operation, and Shutdown

2. Check that the oil level is correct. The correct oil level is centered in the bullseye sight

glass, when the pump is not in operation. During operation, bullseye sight gives a false oil
level reading. Shown is general schematic. Oil level is below outer race of bearing.

1. Plug
2. Reservoir
3. Main body

Lubricate the bearings with pure or purge-oil mist (optional)

NOTICE:
Do not expose an idle pump to freezing conditions. Drain all liquid that is inside the pump and
the cooling coils. Failure to do so can cause liquid to freeze and damage the pump.

Before lubricating with purge-oil mist, make sure that the bearing frame is properly lubricated.
See Lubricate the bearings with oil.
The oil requirements for ring-oil-lubricated bearings also apply to oil-mist-lubricated bearings.

NOTICE:
Oil mist is recommended for use on ball bearing arrangements only. See Convert to oil-mist
lubrication.

1. Prepare the oil-mist generator according to the manufacturer's instructions.
2. Connect the oil-mist supply lines to the oil-ring inspection plug connections.