Commissioning, Startup, Operation, and Shutdown

Group

Nameplate radial bearing

Temperature threshold for hot
doweling

S

6407

Not required

M

6309

L

6312

660°F (349°C)

XL1
XL2

6217

550°F (288°C)

XL3

6317

495°F (257°C)

XL4

6320

430°F (221°C)

XL5

6224

365°F (185°C)

XL6

6224

330°F (166°C)

When the driver is mounted at the factory, the pump is doweled for both cold and hot
applications; the driver is not doweled in order to allow for final field alignment. When the driver
is mounted in the field, the pump is not doweled. Therefore, these doweling procedures,
typically done at the factory, must be done in the field.

NOTICE:
You should dowel only after completing the final alignment.

Dowel for motor installation

1. Center the pump on its pedestal so that the hold-down bolts are centered in the tapped

holes of the pump pedestal.

2. Place the motor on the baseplate with the proper shaft separation (DBSE = distance

between shaft ends).

3. Tighten the pump hold-down bolts.
4. After you have determined the correct motor location on the motor pedestals, mark the

location of the motor on the pedestals with a hole punch through the hold-down bolt holes
in the motor feet.

5. Remove the motor, then drill and tap the punched holes on the motor pedestal.

NOTICE:
Scribe the motor shims in order to return them to the correct location on the motor pedestal.

6. Set the motor back onto the baseplate with the shims in the correct location. Tighten the

hold-down bolts.

7. Loosen the pump and motor hold-down bolts. Confirm that the pump and motor are not

bolt-bound in order to make sure that the final drilled holes will be correctly located.

NOTICE:
Do not dowel the pump prior to this procedure because you will not be able to move the
pump on its pedestals.

Dowel for cold service

Required tools:

• Two number 7 taper pins

• One number 7 taper pin reamer

• 21/64 in. or "Q" size drill

• Hardwood block or soft-faced hammer

Model 3640 Installation, Operation, and Maintenance Manual