Maintenance

Impeller areas to inspect

A. Shroud
B. Wear ring
C. Vane

Oil ring replacement

Oil rings must be as round as possible in order to function properly. Replace oil rings if they are
worn, distorted, or damaged beyond reasonable repair.

Impeller locknut areas to inspect

Locknut surfaces must be smooth and free of grooves and scratches, especially in the areas
indicated by arrows in the figure. Also check the outside diameter of the locknuts.

Cartridge mechanical seal replacement

Cartridge-type mechanical seals should be serviced by the seal manufacturer. Refer to the
instructions from the mechanical seal manufacturer for assistance.

Coupling guard replacement

Repair or replace the coupling guard if you notice corrosion or other defects.