1 eth configuration, 2 setting the rs-232/rs-485 baud rate dip-switches, Setting the rs-232/rs-485 baud rate dip-switches – Kramer Electronics TP-410 User Manual
Page 23: Figure 13: tp-410 baud rate dip-switches
Advertising

20
TP-410 - The SETUP DIP-switches
7.1.1
ETH Configuration
To configure the Ethernet parameters, set DIP-switches 1 to 4 to ON (ON-ON-ON-
ON), turn the power off and then turn the power on again.
Use the Kramer K-UPLOAD software to configure the Ethernet.
The latest version of K-UPLOAD and installation instructions can be
downloaded from the Kramer Web site a
7.2
Setting the RS-232/RS-485 Baud Rate DIP-switches
DIP-switches 5, 6 and 7 set the serial port baud rate.
In a multiple device configuration, all devices must be set to the same
baud rate.
Figure 13: TP-410 Baud Rate DIP-switches
Baud Rate
DIP-switch
5
6
7
1200
OFF
OFF
OFF
2400
ON
OFF
OFF
4800
OFF
ON
OFF
9600 (default)
ON
ON
OFF
19200
OFF
OFF
ON