Kramer protocol 2000 – Kramer Electronics VP-12x8 User Manual

Page 31

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Kramer Protocol 2000

28

Table 9: Instruction Codes for Protocol 2000

Note: All values in the table are decimal, unless otherwise stated.

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

#

DESCRIPTION

INPUT

OUTPUT

NOTE

0

RESET VIDEO

0

0

1

1

SWITCH VIDEO

Set equal to video input

which is to be switched

(0 = disconnect)

Set equal to video output which is

to be switched

(0 = to all the outputs)

2

3

STORE VIDEO STATUS

Set as SETUP #

0 - to store

1 - to delete

2, 3

4

RECALL VIDEO STATUS

Set as SETUP #

0

2, 3

5

REQUEST STATUS OF A

VIDEO OUTPUT

Set as SETUP #

Equal to output number whose

status is reqd

4, 3

15

REQUEST WHETHER SETUP

IS DEFINED

SETUP #

0 - for checking if setup is defined 8

16

ERROR / BUSY

0

0 - error

1 - invalid instruction

2 - out of range

3 - machine busy

9

30

LOCK FRONT PANEL

0 - Panel unlocked

1 - Panel locked

0

2

31

REQUEST WHETHER PANEL

IS LOCKED

0

0

16

57

SET AUTO-SAVE

I3 - no save

I4 - auto-save

0

12, 2

61

IDENTIFY MACHINE

1 - video machine name

0 - Request first 4 digits

13

62

DEFINE MACHINE

1 - number of inputs

2 - number of outputs

3 - number of setups

1 - for video

14

63

EXTENDED DATA

7 MSBs for INPUT data

7 MSBs for OUTPUT data

NOTES on the above table:

NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to

the switchers, it will reset according to the present power-down settings.

NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if

the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the

HEX code

01

85

88

83

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output 7

via the front panel keypad, then the switcher will send HEX codes:

41

81

87

83

to the PC.

When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by

sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).

NOTE 3 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those

used for Store and Recall).

NOTE 4 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are

returned, and the OUTPUT is assigned the value of the INPUT. For example, in instruction 5, if machine number 5 requests

the status of a video output, the reply to the HEX code:

05

80

82

85

would be HEX codes

45

80

81

85

NOTE 8 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 0 if the setup is not

defined / no valid input is detected; or 1 if it is defined / valid input is detected.

NOTE 9 - An error code is returned to the PC if an invalid instruction code was sent to the switcher, or if a parameter

associated with the instruction is out of range (e.g. trying to save to a setup greater than the highest one, or trying to switch an

input or output greater than the highest one defined). This code is also returned to the PC if an RS-232 instruction is sent

while the machine is being programmed via the front panel. Reception of this code by the switcher is not valid.