Bit 5 – Don’t care.

OVR – Machine number override.

M4…M0 – MACHINE NUMBER.

Used to address machines in a system via their machine numbers.

For a single machine controlled via the serial port, always set M4…M0 = 1, and make sure that the machine itself is

configured as MACHINE NUMBER = 1.

When several machines are controlled from a single serial

port, they are usually configured together with each machine having an individual machine number. If the OVR bit is set, then

all machine numbers will accept (implement) the command, and the addressed machine will reply.

Table 20: Instruction Codes for Protocol 2000

Note: All values in the table are decimal, unless otherwise stated.

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

NOTE

#

DESCRIPTION

INPUT

OUTPUT

0

RESET VIDEO

0

0

1

1

SWITCH VIDEO

Set equal to video input

which is to be switched

(0 = disconnect)

Set equal to video output which is

to be switched

(0 = to all the outputs)

2

2

SWITCH AUDIO

Set equal to audio input

which is to be switched

(0 = disconnect)

Set equal to audio output which

is to be switched

(0 = to all the outputs)

2

3

STORE VIDEO STATUS

Set as SETUP #

0 - to store

1 - to delete

2, 3

4

RECALL VIDEO STATUS

Set as SETUP #

0

2, 3

5

REQUEST STATUS OF A

VIDEO OUTPUT

Set as SETUP #

Equal to output number whose

status is reqd

4, 3

6

REQUEST STATUS OF AN

AUDIO OUTPUT

Set as SETUP #

Equal to output number whose

status is reqd

4, 3

8

BREAKAWAY SETTING

0

0 - audio-follow-video

1 - audio breakaway

2

11

REQUEST BREAKAWAY

SETTING

Set as SETUP #

0 - Request audio breakaway

setting

3, 4, 6

15

REQUEST WHETHER SETUP

IS DEFINED / VALID INPUT IS

DETECTED

SETUP #

or

Input #

0 - for checking if setup is defined

1 - for checking if input is valid

8

16

ERROR / BUSY

For invalid / valid input

(i.e. OUTPUT byte = 4

or OUTPUT byte = 5),
this byte is set as the

input #

0 - error

1 - invalid instruction

2 - out of range

3 - machine busy

4 - invalid input

5 - valid input

6 - RX buffer overflow

9, 25

22

SET AUDIO PARAMETER

Equal to input / output

number whose parameter

is to be set

(0 = all)

Set as parameter value

2, 24

24

INCREASE / DECREASE AUDIO

PARAMETER

Equal to input / output

number whose parameter

is to be increased /

decreased

(0 = all)

0 - increase output

1 - decrease output

2 - increase left output

3 - decrease left output

4 - increase right output

5 - decrease right output

6 - increase input

7 - decrease input

8 - increase left input

9 - decrease left input

10 -increase right input

11 - decrease right input

2

25

REQUEST AUDIO PARAMETER Equal to input / output

number whose parameter

is requested

0

6, 24

30

LOCK FRONT PANEL

0 - Panel unlocked

1 - Panel locked

0

2

31

REQUEST WHETHER PANEL

IS LOCKED

0

0

16