NOTE 8 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 0 if the setup is not

defined / no valid input is detected; or 1 if it is defined / valid input is detected.

NOTE 9 - An error code is returned to the PC if an invalid instruction code was sent to the switcher, or if a parameter

associated with the instruction is out of range (e.g. trying to save to a setup greater than the highest one, or trying to switch an

input or output greater than the highest one defined). This code is also returned to the PC if an RS-232 instruction is sent

while the machine is being programmed via the front panel. Reception of this code by the switcher is not valid.
NOTE 10 – This code is reserved for internal use.

NOTE 13 - This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 2,

5 or 7, the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT. For example, for a 2216,

the reply to the request to send the audio machine name would be (HEX codes):

7D

96

90

81 (i.e. 128dec+ 22dec for 2nd byte, and 128dec+ 16dec for 3rd byte).


If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version

number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in

front of the decimal point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the

request to send the version number would be (HEX codes):

7D

83

85

81 (i.e. 128dec+ 3dec for 2nd byte, 128dec+ 5dec for 3rd byte).


If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’s name is sent. For example, for the

VS-7588YC, the reply to the request to send the first suffix would be (HEX codes):

7D

D9

C3

81 (i.e. 128dec+ ASCII for “Y”; 128dec+ ASCII for “C”).


NOTE 14 - The number of inputs and outputs refers to the specific machine which is being addressed, not to the system. For

example, if six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code
3E

82

81

82 (ie. request the number of outputs)

would be HEX codes
7E

82

90

82

ie. 16 outputs

NOTE 16 - The reply to the “REQUEST WHETHER PANEL IS LOCKED” is as in NOTE 4 above, except that here the

OUTPUT is assigned with the value 0 if the panel is unlocked, or 1 if it is locked.

NOTE 19 – After this instruction is sent, the unit will respond to the ASCII command set defined by the OUTPUT byte. The

ASCII command to operate with the HEX command set must be sent in order to return to working with HEX codes.

NOTE 24 – Further information needed in instructions 21, 22, 25 and 26, is sent using instruction 42 – which is sent prior to

the instruction. For example, to request the audio gain value of right input # 9, send hex codes

2A

84

80

81

and then send HEX codes

19

89

81

81.

To set MIX mode, send hex codes
2A 81 84 81
and then send HEX codes

16

NOTE 25 – For units which detect the validity of the video inputs, Instruction 16 will be sent whenever the unit detects a

change in the state of an input (in real-time).
For example, if input 3 is detected as invalid, the unit will send the HEX codes

10

83

84

81

If input 7 is detected as valid, then the unit will send HEX codes

10

87

85

81

Advertising