Specifications, Specifications models a-as-1, wur-1 – WIKA WUR-1 User Manual

Page 9

Advertising
background image

GB

WIKA operating instructions attachable indicator, models A-AS-1, WUR-1

9

2437704.05 10/2012 GB/D/F/E

Specifications

Models A-AS-1, WUR-1

Switching output

Individually adjustable via external control keys

Number

2 x NPN open-collector (with bayonet connector: 1 x NPN

open-collector)

Galvanically-isolated switching outputs for 4 ... 20 mA

Function

Normally open, normally closed

Adjustment

Freely-adjustable in the range 1 ... 99 % of span

Temperature error

< 0.1 % of span/10 K

Accuracy

≤ 0.5 % of span ±1 digit

Max. switching current

300 mA

Display of switch status

LED

Response time

< 15 ms

Hysteresis

0.5 % (fixed)

Permissible temperature ranges

Ambient

-30 ... +85 °C

Storage

-30 ... +85 °C

Compensated

-20 ... +80 °C

Temperature error

< 0.1 % of span/10 K

CE-mark

EMC directive 2004/108/EC, EN 61326 emission

(group 1, class B) and interference immunity (industrial

application)

Ingress protection

IP 65 to IEC 60529

Shock resistance

100 g to IEC 60068-2-27 (mechanical shock)

Vibration resistance

5 g at 10 ... 2,000 Hz to IEC 60068-2-6 (vibration at

resonance)

Electrical safety

Short-circuit resistance

Sig

+

to 0V (short-term)

Reverse polarity protection

U

B+

to 0V (short-term)

Weight

50 g

3. Specifications

For further specifications see WIKA data sheet AC 80.09, PE 87.20 and the order documentation.