WIKA T53 User Manual

Page 16

Advertising
background image

16

 .6 .10 .Measurement .of .voltage .(linear) .with .one .sensor: .

PRIMARY_VALUE_UNIT . . . . . = .µV, .mV .or .V . .
LIN_TYPE . . . . . . . . . . . . . . . . = .No .linearisation . .
LIN_TYPE_ . . . . . . . . . . . . . . = .N/A .(ignored .in .setup .check) . .
SENSOR_MEAS_TYPE . . . . . . = .PV .= .SV_1, .SV_ .not .available . .
SENSOR_CONNECTION . . . . = .N/A .(ignored .in .setup .check) . .
SENSOR_CONNECTION_ . . = .N/A .(ignored .in .setup .check) . .
RJ_TYPE . . . . . . . . . . . . . . . . . = .N/A .(ignored .in .setup .check) . .
Connections: .

 .6 .11 .Measurement .of .voltage .(linear) .with .two .sensors: .

PRIMARY_VALUE_UNIT . . . . . = .µV, .mV .or .V . .
LIN_TYPE . . . . . . . . . . . . . . . . = .No .linearisation . .
LIN_TYPE_ . . . . . . . . . . . . . . = .No .linearisation . .
SENSOR_MEAS_TYPE . . . . . . = .Anything, .but .not ."PV .= .SV_1, .SV_ .not .available" . .
SENSOR_CONNECTION . . . . = .N/A .(ignored .in .setup .check) . .
SENSOR_CONNECTION_ . . = .N/A .(ignored .in .setup .check) . .
RJ_TYPE . . . . . . . . . . . . . . . . . = .N/A .(ignored .in .setup .check) . .
Connections: .

 .6 .1 .Measurement .of . .potentiometers .(with .Linear .interpolation .linearisation): .

PRIMARY_VALUE_UNIT . . . . . . = .% . .
LIN_TYPE . . . . . . . . . . . . . . . . . = .Table .Linearisation . . .
LIN_TYPE_ . . . . . . . . . . . . . . . = .Table .Linearisation .(same .table .as .sensor .1) .
SENSOR_MEAS_TYPE . . . . . . . = .Anything, .but .not ."PV .= .SV_1, .SV_ .not .available" . .
SENSOR_CONNECTION . . . . . = .Default .set .to .3-wire . .
SENSOR_CONNECTION_ . . . = .Default .set .to .3-wire . .
RJ_TYPE . . . . . . . . . . . . . . . . . . = .N/A .(ignored .in .setup .check) .
Connections: .

The .coordinates .(x,y) .describing .the .linear .interpolation .linearisation .must .be .entered .in .PR_
CUST_LIN .Block .(PA .Slot .4) . .See . .9 . .Linear .Interpolation .Linearisation, .Paramter .List .for .
further .details . . .
Example: . .
The .coordinates .for .converting .the .signal .from .a .logarithmic .potentiometer .to .a .linear .signal .

TAB_ACTUAL_NUMBER . = .10 .(number .of .linearisation .points .to .follow .up .to .max .50) . .
TAB_XY_VALUE1 . .

= .0,0; .-100 .

TAB_XY_VALUE . .

= .0,1; .0 .

TAB_XY_VALUE3 . .

= .0,; .100 .

TAB_XY_VALUE4 . .

= .0,4; .00 .

Connections .with .two .sensors .
can .be .configured .for . .
 .measurements, .difference, .
average .or .redundancy

Connections .with .two .sensors .
can .be .configured .for . .
 .measurements, .difference, .
average .or .redundancy

Advertising