AC ELECTRICAL CHARACTERISTICS

Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; T

A

= -10°C to +70°C (Commercial Grade);

T

A

= -40°C to +85°C (Automotive Grade); C

L

= 15 pF.

Notes: 4.

1 UI (unit interval) corresponds to t

SYS_CLK

or 1/f

SYS_CLK

.

5.

t

CS

represents the time from the removal of CLK_IN by which CLK_IN must be re-applied to ensure that

PLL_OUT continues while the PLL re-acquires lock. This timeout is based on the internal VCO frequen-
cy, with the minimum timeout occurring at the maximum VCO frequency. Lower VCO frequencies will
result in larger values of t

CS

.

6.

Only valid in clock skipping mode; See

“CLK_IN Skipping Mode” on page 14

for more information.

7.

f

CLK_OUT

= 24.576 MHz; Sample size = 10,000 points; AuxOutSrc[1:0] = 11.

8.

In accordance with AES-12id-2006 section 3.4.2. Measurements are Time Interval Error taken with 3rd
order 100 Hz to 40 kHz bandpass filter.

9.

In accordance with AES-12id-2006 section 3.4.1. Measurements are Time Interval Error taken with 3rd
order 100 Hz Highpass filter.

10. 1 UI (unit interval) corresponds to t

CLK_IN

or 1/f

CLK_IN

.

11. The frequency accuracy of the PLL clock output is directly proportional to the frequency accuracy of the

reference clock.

Parameters

Symbol

Conditions

Min

Typ

Max

Units

Crystal Frequency
Fundamental Mode XTAL

f

XTAL

RefClkDiv[1:0] = 10
RefClkDiv[1:0] = 01
RefClkDiv[1:0] = 00

8

16
32

-
-
-

18.75

37.5

50

MHz
MHz
MHz

Reference Clock Input Frequency

f

REF_CLK

RefClkDiv[1:0] = 10
RefClkDiv[1:0] = 01
RefClkDiv[1:0] = 00

8

16
32

-
-
-

18.75

37.5

75

MHz
MHz
MHz

Reference Clock Input Duty Cycle

D

REF_CLK

45

-

55

%

Internal System Clock Frequency

f

SYS_CLK

8

18.75

MHz

Clock Input Frequency

f

CLK_IN

50 Hz

-

30

MHz

Clock Input Pulse Width (

Note 4

)

pw

CLK_IN

f

CLK_IN

< f

SYS_CLK

/96

f

CLK_IN

> f

SYS_CLK

/96

2

10

-
-

-
-

UI
ns

Clock Skipping Timeout

t

CS

(Notes

5

,

6

)

20

-

-

ms

Clock Skipping Input Frequency

f

CLK_SKIP

(

Note 6

)

50 Hz

-

80

kHz

PLL Clock Output Frequency

f

CLK_OUT

6

-

75

MHz

PLL Clock Output Duty Cycle

t

OD

Measured at VD/2

45

50

55

%

Clock Output Rise Time

t

OR

20% to 80% of VD

-

1.7

3.0

ns

Clock Output Fall Time

t

OF

80% to 20% of VD

-

1.7

3.0

ns

Period Jitter

t

JIT

(

Note 7

)

-

70

-

ps rms

Base Band Jitter (100 Hz to 40 kHz)

(Notes

7

,

8

)

-

50

-

ps rms

Wide Band JItter (100 Hz Corner)

(Notes

7

,

9

)

-

175

-

ps rms

PLL Lock Time - CLK_IN (

Note 10

)

t

LC

f

CLK_IN

< 200 kHz

f

CLK_IN

> 200 kHz

-
-

100

1

200

3

UI

ms

PLL Lock Time - REF_CLK

t

LR

f

REF_CLK

= 8 to 75 MHz

-

1

3

ms

Output Frequency Synthesis Resolution (

Note 11

)

f

err

High Resolution

High Multiplication

0
0

-
-

±0.5

±112

ppm
ppm