Control port switching characteristics- i·c format, Cs2200-cp, Control port switching characteristics- i²c format – Cirrus Logic CS2200-CP User Manual

Page 8

Advertising
background image

CS2200-CP

8

DS759F2

CONTROL PORT SWITCHING CHARACTERISTICS- I²C FORMAT

Inputs: Logic 0 = GND; Logic 1 = VD; C

L

= 20 pF.

Notes: 8.

Data must be held for sufficient time to bridge the transition time, t

f

, of SCL.

Parameter

Symbol

Min

Max

Unit

SCL Clock Frequency

f

scl

-

100

kHz

Bus Free-Time Between Transmissions

t

buf

4.7

-

µs

Start Condition Hold Time (prior to first clock pulse)

t

hdst

4.0

-

µs

Clock Low Time

t

low

4.7

-

µs

Clock High Time

t

high

4.0

-

µs

Setup Time for Repeated Start Condition

t

sust

4.7

-

µs

SDA Hold Time from SCL Falling

(

Note 8

)

t

hdd

0

-

µs

SDA Setup Time to SCL Rising

t

sud

250

-

ns

Rise Time of SCL and SDA

t

r

-

1

µs

Fall Time SCL and SDA

t

f

-

300

ns

Setup Time for Stop Condition

t

susp

4.7

-

µs

Acknowledge Delay from SCL Falling

t

ack

300

1000

ns

Delay from Supply Voltage Stable to Control Port Ready

t

dpor

100

-

µs

t

buf

t

hdst

t

hdst

t

low

t r

t f

t

hdd

t

high

t sud

t sust

t susp

Stop

Start

Start

Stop

Repeated

SDA

SCL

VD

t

dpor

Figure 2. Control Port Timing - I²C Format

Advertising