Table 4-9, Cs35l32 – Cirrus Logic CS35L32 User Manual

Page 27

Advertising
background image

DS963F4

27

CS35L32

4.12 Signaling Format

4.12.2 Transmitting Data from a Single-CS35L32 Configuration

For a single CS35L32, the user clears

SHARE

(see

p. 39

). When transmitting data via the ADSP, the monitor data is

packed as shown in

Table 4-9

: left channel VMON[15:0], VPMON[7:0] and right channel IMON[15:0], STATUS.

Signal
Monitoring

,

Section 4.8

.

VMON_OVFL
(VMON overflow)

xMON overflow. Indicates the overrange status in the VMON, IMON, or VPMON ADC signal path

0 (Default) No clipping has occurred anywhere in the ADC signal path.
1 Clipping has occurred in the ADC signal path.

The programming of IMON_SCALE may cause IMON_OVFL to be set. See

Section 7.20

.

IMON_OVFL
(IMON overflow)
VPMON_OVFL
(VPMON overflow)
VMON
(voltage monitor)

16- or 12-bit representation of the voltage across the load, sensed on VSENSE±

IMON
(current monitor)

16- or 12-bit representation of the voltage sensed across an external 0.1-



resistor in series with the

SPKOUT+ terminal, sensed on ISENSE±

VPMON
(battery voltage)

8-bit representation of the voltage present on VP pin, i.e., the system’s battery voltage, sensed
internally

LED Driver

Section 4.9

.

LED12_FLEV
(LED12 flash event)

LED1 or LED2 flash event (Logical OR of

LED1_FLEV

and

LED2_FLEV

, see

p. 43

)

0 (Default) No driver flash current delivered to either LED1 or LED 2
1 Flash current delivered to LED1, LED2, or both

LED12_MVEV
(LED12 Movie Mode
event)

LED1 or LED2 movie event (Logical OR of

LED1_MVEN

and

LED2_MVEV

, see

p. 43

)

0 (Default) No driver movie current delivered to either LED1 or LED 2
1 Movie current delivered to LED1, LED2, or both

LED_TIMERON
(flash timer)

Flag indicating whether the flash timer is On. See

Section 7.22

.

0 (Default) LED Flash timer Off
1 LED Flash timer On

Power down

PDN_DONE
(power-down done)

Indicates whether the CS35L32 is completely powered down and MCLK can be stopped. See

Section 7.20

.

0 Not completely powered down. PDN_DONE = 0 if any blocks still require MCLK

INT

. After

powering down using PDN_ALL or the individual power-down bits, the CS35L32 transitions to a
powered-down state, after which, PDN_DONE is set and MCLK

INT

can be removed.

1 (Default) Powered down

Table 4-9. SDOUT Monitor Data Positioning (Single CS35L32

)

Bit

Bit Number Left-Channel Data Contents Right-Channel Data Contents

MSB

1

VMON[15]

IMON[15]

MSB – 1

2

VMON[14]

IMON[14]

MSB – 15

16

VMON[0]

IMON[0]

MSB – 16

17

VPMON[7]

AMP_SHORT

MSB – 17

18

VPMON[6]

OTW

MSB – 18

19

VPMON[5]

OTE

MSB – 19

20

VPMON[4]

VMONIMON_OVFL

MSB – 20

21

VPMON[3]

VPMON_OVFL

MSB – 21

22

VPMON[2]

PDN_DONE

MSB – 22

23

VPMON[1]

BOOST_CURLIM

MSB – 23

24

VPMON[0]

LED_TIMERON

MSB – 24

25

Reserved

VMON_OVFL

MSB – 25

26

Reserved

IMON_OVFL

MSB – 26

27

Reserved

UVLO

MSB – 27

28

Reserved

BOOST_OVERROR

MSB – 28

29

Reserved

LED12_FLEV

MSB – 29

30

Reserved

LED12_MVEV

MSB – 30

31

Reserved

Reserved

MSB – 31

32

Reserved

Reserved

Table 4-8. SDOUT Monitor Data Description (Cont.)

Function

Data Descriptor

Description

Advertising