Adc digital filter characteristics, Cs42l55 adc digital filter characteristics – Cirrus Logic CS42L55 User Manual

Page 13

Advertising
background image

DS773F1

13

CS42L55

ADC DIGITAL FILTER CHARACTERISTICS

Notes:

8.

Response is clock-dependent and will scale with Fs. Note that the response plots (

Figures 27

to

30 on

page 70

) have been normalized to Fs and can be de-normalized by multiplying the X-axis scale by Fs.

HPF parameters are for Fs = 48 kHz.

9.

Characteristics are based on the default setting in register

“HPF Control (Address 09h)” on page 47

.

10. Settling time decreases at higher corner frequency settings.

Parameter

(Note 8)

Min

Typ

Max

Unit

Frequency Response (20 Hz to 20 kHz)

-0.07

-

+0.02

dB

Passband

to -0.05 dB corner

to -3 dB corner

-
-

0.421
0.495

-
-

Fs
Fs

Stopband

0.52

-

-

Fs

Stopband Attenuation

33

-

-

dB

Total Group Delay

-

7.6/Fs

-

s

High-Pass Filter Characteristics (48 kHz Fs)

(Note 9)

Passband

to -3.0 dB corner

to -0.05 dB corner

-
-

1.87

17.15

-
-

Hz
Hz

Passband Ripple

-

-

0.15

dB

Phase Deviation

@ 20 Hz

-

5.3

-

Deg

Filter Settling Time

(Note 10)

-

10

5

/Fs

-

s