When the charge pump transitions from the higher set of rail voltages to the lower set, there is a one sec-
ond delay before the charge pump supplies the lower rail voltages to the amplifiers. This hysteresis en-
sures that the charge pump doesn't toggle between the two rail voltages as signals approach the clip
threshold. It also prevents clipping in the instance of repetitive high level transients in the input signal. The
timing diagram for this transitional behavior is detailed in

Figure 16

.

+VCP

-VCP

-VCP

2

+VCP

2

Ideal Transition

Ideal Transition

Actual Transition caused

by VHPFILT Capacitor

Actual Transition caused

by VHPFILT Capacitor

Time

Figure 15. VHPFILT Transitions

Output Level

-10 dB

VCP

2

VCP

- VCP

- VCP

2

Amplifier Rail

Voltage

1 second

Time

Time

Figure 16. VHPFILT Hysteresis