3 auto-boot mode using eeprom, 1 auto-boot configuration, Cs5460a – Cirrus Logic CS5460A User Manual

Page 24: Cs5460a eeprom

Advertising
background image

CS5460A

24

DS487F5

pulse, one of the output pins (either EOUT or ED-
IR) changes state. When the CS5460A must issue
another energy pulse, the other output changes
state. The direction the motor will rotate is deter-
mined by the order of the state changes. When en-

ergy is positive, EOUT will lead EDIR such that the
EOUT pulse train will lead the EDIR pulse train by
~1/4 of the periods of these two pulse train signal.
When energy is negative, EDIR will lead EOUT in
a similar manner. See Figure 12.

3.3 Auto-boot Mode Using EEPROM

The CS5460A has a MODE pin. When the MODE
pin is set to logic low, the CS5460A is in normal op-
erating mode, called host mode. This mode de-
notes the normal operation of the part, that has
been described so far. But when this pin is set to
logic high, the CS5460A auto-boot mode is en-
abled. In auto-boot mode, the CS5460A is config-
ured to request a memory download from an
external serial EEPROM. The download sequence
is initiated by driving the RESET pin to logic high.
Auto-boot mode allows the CS5460A to operate
without the need for a microcontroller. Note that if
the MODE pin is left unconnected, it will default to
logic low because of an internal pull-down on the
pin.

3.3.1 Auto-boot Configuration

Figure 13 shows the typical connections between
the CS5460A and a serial EEPROM for proper au-
to-boot operation. In this mode, CS and SCLK are
driven outputs. SDO is always an output. During
the auto-boot sequence, the CS5460A drives CS
low, provides a clock output on SCLK, and drives
out-commands on SDO. It receives the EEPROM
data on SDI. The serial EEPROM must be pro-
grammed with the user-specified commands and
register data that will be used by the CS5460A to
change any of the default register values (if de-
sired) and begin conversions.

Figure 13 also shows the external connections that
would be made to a calibrator device, such as a PC

EOUT

EDIR

Positive Energy

Negative Energy

...

...

...

...

Figure 12. Stepper Motor Format on EOUT and EDIR

CS5460A

EEPROM

/EOUT

/EDIR

MODE

SCK

SDI

SDO

/CS

SCK

SO

SI

/CS

Connector to

Calibrator

VD+

5 K

5 K

Mech. Counter

Stepper Motor

or

Figure 13. Typical Interface of EEPROM to CS5460A

Advertising