Cs5484, 72 temperature offset (t, 73 calibration scale (scale) – Cirrus Logic CS5484 User Manual

Page 61: 74 v-channel zero-crossing threshold (vzx, 75 i-channel zero-crossing threshold (izx, 76 zero-crossing number (zx

Advertising
background image

CS5484

DS981F3

61

6.6.72 Temperature Offset (T

OFF

)

Page 16, Address 55

Default = 0x D5 3998

Register T

OFF

is used to offset the Temperature register (T), and is a two's complement value in the range of

-128.0

value128.0 (°C), with the binary point to the right of bit 16.

Register T can be rescaled by the application using the T

GAIN

and T

OFF

registers. Refer to section

7.3 Tem-

perature Sensor Calibration

on page 65 for more information.

6.6.73 Calibration Scale (Scale)

Page18, Address 63

Default = 0 x4C CCCC (0.6)

The Scale register is used in the gain calibration to set the level of calibrated results of I-channel RMS. During
gain calibration, the Ix

RMS

results register is divided into the Scale register. The quotient is put into the Ix

GAIN

register. This is a two's complement value in the range of -1.0

 value 1.0, with the binary point to the right of

the MSB. Negative values are not used.

6.6.74 V-Channel Zero-crossing Threshold (VZX

LEVEL

)

Page 18, Address 58

Default = 0x10 0000 (0.125)

VZX

LEVEL

is the level that the peak instantaneous voltage must exceed for the zero-crossing detection to

function. This is a two's complement value in the range of -1.0

value<1.0, with the binary point to the right of

the MSB. Negative values are not used.

6.6.75 I-Channel Zero-crossing Threshold (IZX

LEVEL

)

Page 18, Address 24

Default = 0x10 0000 (0.125)

IZX

LEVEL

is the level that the peak instantaneous current must exceed for the zero-crossing detection to func-

tion. This is a two's complement value in the range of -1.0

value<1.0, with the binary point to the right of the

MSB. Negative values are not used.

6.6.76 Zero-crossing Number (ZX

NUM

)

Page 0, Address 55

Default = 0x00 0064 (100)

ZX

NUM

is the number of zero crossings used for line frequency measurement. It is an integer in the range of

1 to 8,388,607. Zero should not be used.

MSB

LSB

-(2

7

)

2

6

2

5

2

4

2

3

2

2

2

1

2

0

.....

2

-10

2

-11

2

-12

2

-13

2

-14

2

-15

2

-16

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

2

23

2

22

2

21

2

20

2

19

2

18

2

17

2

16

.....

2

6

2

5

2

4

2

3

2

2

2

1

2

0

Advertising