Setup Screens (two individually controlled pumps) cont’d:

Prime/Purge adjust and activation

Prime and Purge have the following available settings.

***Factory default values shown***

Speed (7 – 749 RPM for the STH & RH and 7 – 599 RPM for the STQ &

STQP)

Run

1. Run = “Start&Stop”. Start prime/purge via keypad “Run” and

stop prime/purge via “Stop”

2. Run = “Ext. Switch”. Start prime/purge via external switch.

Pump will continue to prime/purge until switch is released.

Switch A activates pump A and Switch B activates pump B.

3. Run – “Start&Hold”. Start prime/purge via keypad “Run”.

Prime/purge will continue until the Run button is released.

To adjust either the speed or run method simply press the up

or down

arrow

keys to go to the desired item and then press the enter

key to select. To set the

speed press the up/down arrow keys

until the desired speed is shown. Press

enter

key to save. To set the desired run method press the up/down

arrow keys until the desired run method is shown. Press enter

key to save. To

start the Prime/Purge process use the device chosen (Keypad run button or external
switch). To exit setup press the setup

key and the motor(s) will automatically home

or press the enter

key to go to the next setup screen.

Setup A = Prime

‘ENTER’ FOR NEXT MENU

Speed = 200 rpm
Run = Start&Stop

USE ARROWS TO SELECT

Setup A = Purge

‘ENTER’ FOR NEXT MENU

Speed = 200 rpm
Run = Start&Stop

USE ARROWS TO SELECT