Setup = rs485, Interface = 2 wire device addr. = 5 – FMI PDS100 User Manual
Page 8

Page 8 of 18
Setup Screens (two individually controlled pumps) cont’d
RS485 setup
RS485 has the following available settings for Interface & Device Address
***Factory default values shown***
Interface. 2 wire or 4 wire
Device Address. Up to 31 (address #1 to #31) units can be
independently addressed.
To adjust either the interface type or device address simply press the up
or down
arrow keys to go to the desired item and then press the enter
key. To set the
interface type press the up/down
arrow keys until the desired control method is
shown. Press the enter
key to save. To set the Device Address press the up/down
arrow keys until the desired address is shown. Press the enter
key to
save. The address selected applies to both pumps in a dual pump system. To exit setup
press the setup
key and the motor(s) will automatically home or press the enter
key to go to the next setup screen.
Setup = RS485
‘ENTER’ FOR NEXT MENU
Interface = 2 Wire
Device Addr. = 5
USE ARROWS TO SELECT
IN-PDS100-13A
11/1/13 HW