Roundline Plus Stainless Steel Body Actuators

Force Factor Data

Bore

Code

Force Factor (Area)

Extend

Retract

5/16"

(031)

0.077

0.064

7/16"

(043)

0.15

0.12

9/16"

(056)

0.25

0.22

3/4"

(075)

0.44

0.39

7/8"

(087)

0.6

0.55

1-1/16"

(106)

0.89

0.81

1-1/4"

(125)

1.23

1.08

1-1/2"

(150)

1.77

1.62

1-3/4"

(175)

2.41

2.21

2"

(200)

3.14

2.84

2-1/2"

(250)

4.91

4.61

3"

(300)

7.07

6.63

Force Output Formula
Cylinder Output Force = Force Factor (area) x Air Line Pressure (psi)
Ex: 1-1/16 bore cylinder operating at 80 psi:
Force exerted on the extend: 0.89 x 80 = 71.2 lbs.
Force exerted on the retract: 0.81 x 80 = 55.2 lbs.

Approximate Spring Forces (lbs.)

Bore

Code

Relaxed (lbs)

Compressed (lbs)

5/16"

(031)

0.5

1

7/16"

(043)

1

2

9/16"

(056)

2

4

3/4"

(075)

3

6

7/8"

(087)

3

6

1-1/16"

(106)

3

6

1-1/4"

(125)

7.5

15

1-1/2"

(150)

7

14

1-3/4"

(175)

11

24

2"

(200)

15

30

Dimensions in inches

Air Reservoir

Air Reservoirs are made of the same high-quality stainless steel as the
Series RP Cylinders.

Dimensions — All Dimensions in Inches

Bore

E

EE

J

K

LB

Standard Internal

Lengths

3/4"

0.813

1/8"

0.625

0.187

1.938

1" increments thru 4"

1-1/16"

1.125

1/8"

0.875

0.187

2.375

1" increments thru 8"

1-1/2"

1.562

1/8"

0.875

0.250

2.250

1" increments thru 16"

2"

2.080

1/4"

1.250

0.312

2.875

1" increments thru 16"

2-1/2"

2.610

1/4"

1.750

0.312

2.875

1" increments thru 24"

How to Order
Example:
1-1/16" bore air reservoir with a 3" internal length would be ordered as
follows: AR-1-1/16 x 3