2006-125d

8/13

Elbow connector M12 x 1

Page 4

0250081

Pin-No.

Function

1

+24 V d.c. supply

2

0 ... 10 V feedback

3

Control signal (+VE)

4

Common (supply signal and feedback return)

5

Chassis

Setting

Options

Language

English, Español, Français, Italiano, Deutsch

Pressure units

Bar, atm, kg/cm2, kPa, psi

Password Protection

Protect against unauthorised adjustment of the valve

Off-line Set up

Min Set up

Set pressure between 0…10 Bar and Min – Max Signal

Max Set up

Set pressure between 10…0 Bar and Min – Max Signal

Speed Setting

Change the time taken to ramp between two pressures. (Volume dependent)

Dynamic Response

Allows the Integrator settle time to be set

Dither Amp

Amplitude of the dither on the spool

On-line Set up

Min Set up

Can be used for fine adjustment of output pressure at a given signal

Max Set up

Can be used for fine adjustment of output pressure at a given signal

Monitor Set up

Monitor Output

Display feedback for user information.

Green Indicator

Shows power is present and can be set to flash when the output pressure is outside specified limits

Red Indicator

Normally off. Can be set to flash if the output pressure does not reach the required value within a specific time limit. Will also flash when the unit is set to local control.

Local Control

Manual Control

Valve output can be set using the arrow keys

Factory Defaults

Option to resets the valve to the Factory default settings.

Single manifold

Page 4

ZZ5M00

Connecting plugs

Electrical connector pin looking

into the end of the instrument

Valve built in user adjustable settings

Characteristic curves

Manifold mount assembly to ISO 2 sub base

O-rings, flat seal and screws are included

1

2

5

3

4

10

9
8
7
6
5
4
3
2
1
0

0

200

400

600

800

1000 1200 1400 Nl/min

bar

10

4

2

0

6

8

200

0

400

600

800

1000

Nl/min

bar

Outlet pressure

Outlet pressure

Flow

Flow

Forward flow characteristics

(supply pressure 11 bar)

Relief flow characteristics

(supply pressure 9 bar)