B72g, Installation & maintenance instructions – Norgren B72G Series Installation Instructions User Manual

Page 2

Advertising
background image

ASSEMBLY
1. Lubricate the following items with o-ring grease.

4 (Thrust washer) - outer circumference and both sides.
5, 7 (Adjusting screw) - threads and tip.
18, 31, 40 (Manual drain body) - the portion of the body

that contacts the bowl, and the hole that
accommodates the stem of drain valve (19, 32, 41).

54 (Center-post) - Bore for valve (57).
57 (Valve) - stem.
23, 28, 36, 37, 45, 50, 58, 59 - (O-rings)

2. Assemble the unit as shown on the exploded view. Push

bowl, or bowl with guard, into body and turn fully
clockwise.

3. Torque Table

Item

Torque in Nm (Inch-Pounds)

2, 9 (Screw)

2,3 to 2,8 (20 to 25)

22, 35, 44, 25, 36B, 45B (Nut) 2,3 to 2,8 (20 to 25)
46 (Screw)

1,9 to 2,5 (17 to 22)

52 (Baffle)

0,5 to 0,7 (4 to 6)

54 (Center-post)

0,7 to 0,9 (6 to 8)

B72G

Installation & Maintenance

Instructions

CAUTION

Water vapor will pass through these units and could
condense into liquid form downstream as air temperature
drops. Install an air dryer if water condensation could have
a detrimental effect on the application.

WARNING

These products are intended for use in industrial

compressed air systems only. Do not use these products
where pressures and temperatures can exceed those listed
under Technical Data.

Polycarbonate plastic bowls can be damaged and

possibly burst if exposed to such substances as certain
solvents, strong alkalies, compressor oils containing ester-
based additives or synthetic oils. Fumes of these
substances in contact with the polycarbonate bowl,
externally or internally, can also result in damage. Clean
with warm water only.

Use metal bowl in applications where a plastic bowl

might be exposed to substances that are incompatible with
polycarbonate.

If outlet pressure in excess of the filter/regulator

pressure setting could cause downstream equipment to
rupture or malfunction, install a pressure relief device
downstream of the filter/regulator. The relief pressure and
flow capacity of the relief device must satisfy system
requirements.

The accuracy of the indication of pressure gauges can

change, both during shipment (despite care in packaging)
and during the service life. If a pressure gauge is to be
used with these products and if inaccurate indications may
be hazardous to personnel or property, the gauge should be
calibrated before initial installation and at regular intervals
during use.

Before using these products with fluids other than air,

for non industrial applications, or for life-support systems
consult Norgren.

IM-160.300.02

(2/00)

Supersedes 7/98

a subsidiary of IMI plc

© Norgren 2000

1

3

4

5

2

12

13

16

14

15

55

54

53

52

58

56

59

57

11

7

8

9

10

6

17

18

27

20

19

30

39

21

23

22

28

29

25

24

26

47

46

49

51

48

41

42

44

50

40

43

45

45A

45C

45B

36B

35

33

32

38

36

36C

31

34

37

36A

Advertising