11-104

Pilot regulators are used to control the outlet
pressure of a pilot operated regulator (ordered
separately)

The pilot regulator is installed in an accessible

location in the compressed air system; pilot operated
regulator is installed at any point without regard to
accessibility

Feedback pilot regulator provides superior pressure
regulation under changing flow demands where
changes in flow demand are not sudden or cyclic.

Constant bleed feature provides maximum sensitivity
to system changes

Relief feature allows reduction of downstream
pressure when the system is dead-ended

Feedback Pilot Regulator

1/4" Port Size

ISO Symbols

11-104 Feedback Pilot Regulator

with Pilot Operated Regulator

† Outlet pressures can be adjusted to pressures in excess or, and less than, those specified. Do not use these units to control pressures outside of

the specified ranges.

Ordering Information

Model listed is relieving, constant bleed, 5 to 100 psig (0.3 to 7 bar) outlet pressure adjustment range†, with

PTF ports.

Port Size

Type

Model

Weight lb (kg)

Pressure psig (bar)

1/4" PTF

Feedback Pilot

11-104-001

3.38 ( 1.53)

5-105 (.3-7)

1/4" PTF

Feedback Pilot

11-104-002

3.38 ( 1.53)

50-250 (3-17)

Feedback Pilot Regulator Warning

The feedback line must sense the pilot operated regulator outlet pressure
and must be connected before turning on the air supply. If the feedback line
is not connected, the pilot operated regulator outlet pressure will rapidly
increase to the inlet pressure when the adjusting knob on the pilot regulator
is turned clockwise.